A pulse withstanding resistor takes the inrush, gate-drive and surge pulses in a heat pump inverter that crack a general purpose chip. SKVP data show Swedish heat pump sales rose 22 percent in the third quarter of 2026, and Walsin lists 5,560 anti-surge parts at 10 and 20 percent for wide-tolerance RPCA lines. Venatech is the authorised Walsin distributor in Hong Kong.
Venatech Limited, an authorised Walsin distributor in Hong Kong, wrote this for engineers and buyers in Sweden who design or build heat pump electronics: compressor inverters, EC fan drives, circulation pump controllers and the mains input stages in front of them. Walsin Technology (Walsin) is the line we are authorised for; Stackpole Electronics (SEI) is a line we supply, so RPCA lines can be quoted as they stand or crossed to Walsin. On 25 November 2026 we counted the Walsin figures ourselves from our Walsin chip resistor exports (Venatech_ChipR_Upload_*.xlsx, 80 files) and checked our ready stock as at 9 November 2026. Stackpole figures come only from Stackpole’s resistor family page on seielect.com, fetched the same day.
How fast are heat pump sales growing in Sweden in 2026?
22 percent in the third quarter. Finwire reported on Placera on 20 October 2026, citing the Swedish refrigeration and heat pump association SKVP, that heat pump sales in Sweden rose 22 percent in the third quarter of 2026, led by liquid-to-water units at plus 30 percent and air-to-water units at plus 23 percent.
According to the same SKVP data, exhaust air heat pumps rose 6 percent, the villa segment grew 22 percent and the property segment 25 percent, with air-to-water units for properties up 53 percent. Those are SKVP’s figures as Finwire reported them, not ours, and we make no claim about any heat pump maker’s suppliers. Every extra unit carries an inverter board that meets mains surges and switching pulses for its whole service life.
Where does a pulse withstanding resistor sit in a heat pump?
Wherever energy arrives faster than the board can spread it. In a heat pump, pulse withstanding resistors from about 1 ohm to 1 megohm in 0805 to 2512 sit in DC-link pre-charge and discharge paths, IGBT and MOSFET gate resistors, snubbers, mains-side sense dividers and the input filter, where a single surge can be many times the part’s rated power.
A general purpose thick film chip has a narrow trimmed track that a short pulse can crack. A surge part spreads the energy across a wider film, which is why the Stackpole datasheet and Walsin’s datasheet for these series both carry pulse curves. Our note on anti-surge chip resistors explains the construction, and anti-surge vs general purpose, field by field shows what changes on the datasheet.
How many Walsin anti-surge parts cover the Stackpole RPCA range?
5,560 at 10 and 20 percent, 17,180 surge parts in all. We counted 8,340 distinct parts in Walsin’s general anti-surge series, 5,560 of them at 10 or 20 percent, in six sizes from 0603 to 2512; two automotive surge series tagged AEC-Q200 add 5,810 triple power surge parts and 3,030 power surge parts at 0.5 to 5 percent.
Stackpole’s resistor family page, fetched 25 November 2026, describes RPCA as an automotive grade surge withstanding chip resistor in sizes 0402 to 2512, from 0.5 to 20 percent and from 1 ohm to 20 megohm, AEC-Q200 qualified and anti-sulfur, and lists the non-automotive RPC over the same sizes and values. In our Venatech_ChipR_Upload_*.xlsx files, Walsin’s general series covers RPCA’s wide 10 and 20 percent codes directly; its automotive series cover the 0.5 to 5 percent codes.
| Walsin surge subset | Distinct parts | What our export states |
|---|---|---|
| General anti-surge, all | 8,340 | 0603 to 2512, 0.27 ohm to 22 megohm, 5, 10, 20 percent |
| General anti-surge at 10 or 20 percent | 5,560 | 1,054 each in 0805, 1206, 2010, 2512 |
| General anti-surge at 10 or 20 percent in 0603 | 580 | Plus 764 in 1210 |
| Triple power surge (automotive), AEC-Q200 | 5,810 | 0402 to 2512, 1 percent and 5 percent |
| Power surge (automotive), 0603 and 0805 | 3,030 | Includes 1,370 at 0.5 percent |
| All Walsin surge series | 17,180 | Our count, 25 November 2026 |
One quirk matters for your ERP. Most parts in Walsin’s general anti-surge series are written with a space in the export, for example WF12S103 KTL, and only 420 low-ohm codes are written without one. We quote the spaced codes exactly as Walsin writes them; our post on why Walsin part numbers do not paste into your BOM shows how to store them.
Which Walsin part crosses a Stackpole RPCA line?
Most lines from 1 ohm to 1 megohm. For an RPCA brief at 0.5, 1 or 5 percent, Walsin’s automotive surge series match size, value and tolerance with an AEC-Q200 tag; a 10 or 20 percent RPCA line matches in the general anti-surge series, which our export does not tag AEC-Q200, so pick by whether the heat pump board needs the automotive grade.
| Your brief (RPCA style) | Walsin part | Walsin series, value, tolerance, TCR, power (export) | Match / mismatch | Your incumbent |
|---|---|---|---|---|
| 4.7 ohm, 1206, 1 percent | MF12E4R70FTL |
Triple power surge (automotive), 4.7 ohm, 1 percent, 100 ppm, 0.75 W | Match | |
| 10 ohm, 2512, 1 percent | MF25E10R0FTL |
Triple power surge (automotive), 10 ohm, 1 percent, 100 ppm, 2 W | Match | |
| 22 ohm, 2010, 1 percent | MF20E22R0FTL |
Triple power surge (automotive), 22 ohm, 1 percent, 100 ppm, 1 W | Match | |
| 100 kilohm, 1206, 1 percent | MF12E1003FTL |
Triple power surge (automotive), 100 kilohm, 1 percent, 100 ppm, 0.75 W | Match | |
| 1 kilohm, 1210, 1 percent | MF10E1001FTL |
Triple power surge (automotive), 1 kilohm, 1 percent, 100 ppm, 0.75 W | Match | |
| 47 ohm, 0805, 0.5 percent | MK08S47R0DTL |
Power surge (automotive), 47 ohm, 0.5 percent, 100 ppm, 1/3 W | Match | |
| 220 ohm, 1206, 1 percent | MF12E2200FTL |
Triple power surge (automotive), 220 ohm, 1 percent, 100 ppm, 0.75 W | Match, on our shelf | |
| 10 kilohm, 1206, 10 percent | WF12S103 KTL |
General anti-surge, 10 kilohm, 10 percent, 100 ppm, 0.25 W | Match on value and tolerance; no AEC-Q200 tag | |
| 0.47 ohm, 2512, 10 percent | WK25SR470KTL |
General anti-surge, 0.47 ohm, 10 percent, 200 ppm, 1 W | Mismatch: below the 1 ohm RPCA floor |
Have part numbers to quote? Click any Walsin part number in the table to open its page and add it to your RFQ, or upload your BOM for a quote, or cross your current part in VenaMatch. E-mail sales@venatech.com.hk or call (852) 2628 4777. We confirm availability, date code and lead time on each quote.
Check the datasheet. Our export states size, value, tolerance, TCR and rated power. It does not state the single-pulse or repetitive-pulse curve, the surge voltage or the sulfur test. Lay Walsin’s surge curve over the RPCA curve at your own pulse width and repetition rate before you approve the cross, and note that Walsin’s 0805 general anti-surge parts are rated 0.125 W against 1/3 W in the automotive power surge series.
What should a Swedish heat pump maker check before crossing RPCA?
The pulse curve, the grade and the sulfur claim. A Swedish heat pump maker should compare pulse energy at its real pre-charge and gate-drive waveforms, decide whether the board needs an AEC-Q200 tagged part or the general series, and ask about sulfur resistance, because RPCA is listed as anti-sulfur and our Walsin surge export carries no anti-sulfur tag.
If the RPCA was chosen for its anti-sulfur rating, treat that as an open question and ask us for the test data behind Walsin’s datasheet, or consider a Walsin anti-sulfuration series for that position. Safety standards for the appliance and any customer approvals are your compliance team’s call; confirm with your compliance team.
How Venatech helps
Cross the RPCA lines and the rest of the inverter BOM in one upload. Venatech is the authorised Walsin distributor in Hong Kong; VenaMatch decodes part numbers from 18 manufacturers and crosses 800,000+ parts to Walsin, stating size, value, tolerance, TCR and power as match or mismatch.
Paste your RPCA lines into the cross-reference tool, or upload the whole parts list at BOM upload. On our shelf in Hong Kong (snapshot 9 Nov 2026) is MF12E2200FTL, a Walsin triple power surge part in 1206; see ready stock. Other values are sourced to order: request a quote and we source them through our authorised Walsin channel. Stackpole RPCA lines can be quoted too: Stackpole is a line we supply, and Walsin is the line we are authorised for. We serve heat pump and HVAC makers across Sweden from Hong Kong in small lots, for samples, pilot builds and urgent gaps, and confirm availability, date code and lead time on each quote, with no price, lead-time or stock guarantee. The chip resistor range lists every Walsin family.
The short version
- Swedish heat pump sales rose 22 percent in the third quarter of 2026, with liquid-to-water units up 30 percent (SKVP via Finwire on Placera, 20 October 2026).
- Walsin lists 8,340 general anti-surge parts, 5,560 of them at 10 or 20 percent, plus 8,840 AEC-Q200 tagged automotive surge parts.
- RPCA lines at 0.5 to 5 percent match Walsin’s automotive surge series; 10 and 20 percent lines match the general series.
- Check the pulse curve, the grade and the sulfur test before you approve the cross.
Send us your RPCA lines and we will return the Walsin crosses with every difference stated. What pre-charge energy does your inverter’s resistor absorb at power-up?
Related reading
- Anti-surge chip resistors
- Anti-surge vs general purpose resistor, field by field
- Why Walsin part numbers do not paste into your BOM
- Cross-reference tool, BOM upload and ready stock snapshot
Last reviewed: 25 November 2026.
Sources
Fetched 25 November 2026.
- Finwire on Placera, SKVP heat pump sales data for the third quarter of 2026, dated 20 October 2026: https://www.placera.se/telegram/nibe-industrier-branschdata-varmepumpsforsaljningen-okade-22-procent-under-tredje-kvartalet-20261020
- Stackpole Electronics resistor family page, fetched 25 November 2026: https://seielect.com/products/productsearch.asp?SelFamilyID=1
- Venatech Walsin chip resistor exports (Venatech_ChipR_Upload_*.xlsx) and ready stock snapshot dated 9 November 2026, re-measured 25 November 2026.
- Walsin anti-surge chip resistor datasheets, linked from each part page.
Frequently asked questions
Which pulse withstanding resistor crosses a Stackpole RPCA for heat pumps in Sweden?
Walsin’s triple power surge series, tagged AEC-Q200, for 0.5 to 5 percent lines, for example MF25E10R0FTL, 10 ohm, 1 percent and 2 W in 2512; for 10 and 20 percent lines, Walsin’s general anti-surge series.
How many Walsin anti-surge parts are there at 10 and 20 percent?
5,560 of the 8,340 parts in Walsin’s general anti-surge series, counted from our export on 25 November 2026.
Is Walsin’s general anti-surge series AEC-Q200?
Our export does not tag it AEC-Q200. The triple power surge and power surge series are the ones tagged AEC-Q200.
Is the Walsin surge series anti-sulfur like RPCA?
Our export does not tag it as anti-sulfur, so ask us for the test data before you cross an RPCA line in a sulfur-bearing environment.
Do you hold anti-surge resistors on the shelf in Hong Kong?
One line. On our shelf in Hong Kong (snapshot 9 Nov 2026) is MF12E2200FTL, 220 ohm, 1 percent in 1206; other values are sourced to order, so request a quote.
How does Venatech supply Stackpole?
Stackpole is a line we supply, not an authorised line; Venatech is the authorised Walsin distributor in Hong Kong. We quote the Stackpole RPCA alongside the Walsin cross for heat pump makers in Sweden.