High Voltage MLCC for Grid Equipment in Canada: Hitachi Energy Puts 479 Million Canadian Dollars into Ontario, and Walsin Lists 904 X7R Parts at 1 kV or More

For a high voltage MLCC on Canadian grid equipment, Walsin Technology (Walsin) lists 904 X7R part numbers rated 1 kV or more, up to 5 kV, and a 4.7 nF brief at 2 kV or more returns 19 of them in six case sizes. Venatech, Walsin’s authorised distributor in Hong Kong, crosses and quotes them for Canada.


Venatech Limited, an authorised Walsin distributor in Hong Kong, wrote this for a power-electronics or protection engineer in Canada whose boards sit inside transformers, switchgear, relays and grid converters. We parsed Walsin’s MLCC export 00_ALL_MLCC_parts_combined.xlsx (24,026 rows, 23,601 distinct part numbers) and our stock snapshot as at 9 November 2026, and we counted distinct part numbers at each voltage. The news fact names its source and the date we fetched it, 16 November 2026.

What did Hitachi Energy announce in Ontario?

An investment of 479 million Canadian dollars. Evertiq reported on 13 November 2026 that Hitachi Energy will invest 479 million Canadian dollars, more than 330 million US dollars, in its North American insulation and components business, with a 21,000 square metre plant in London, Ontario, that makes pressboard and laminates for transformers.

The report says the site should be complete by 2028 and bring over 100 permanent skilled jobs, with support of 20 million Canadian dollars from the Government of Canada, up to 20 million from the Invest Ontario Fund and 10 million from Natural Resources Canada. It links the project to Canada’s National Electricity Strategy, which aims to double grid capacity by 2050. We add no forecast. What it tells an engineer in Canada is that the grid build-out is turning into factories, and the transformers, monitors and converters that follow all carry high-voltage electronics.

Where does a high voltage MLCC sit in grid equipment?

Wherever a small capacitor must hold kilovolts. In grid equipment, a high voltage MLCC usually works as an RC snubber across a switching device or relay contact, as a coupling or filter capacitor on a voltage-sensing path, or in the isolated supply that powers a gate driver or a monitoring board; 1 kV to 3 kV is the common range.

A transformer monitor reads voltage, current and temperature from inside a high-energy enclosure. A protection relay filters fast transients on its inputs. A STATCOM, battery inverter or grid-tied converter switches hundreds of volts at high dv/dt. Our note on the high-voltage MLCC capacitance limit shows how quickly capacitance falls as rated voltage climbs, and X1/Y1 vs X1/Y2 safety capacitors covers the line-to-ground positions where a safety-certified part is required.

How many high voltage MLCC does Walsin list?

1,874 at 1 kV or more. We counted 1,874 distinct Walsin MLCC part numbers rated 1 kV or more: 970 in NP0 and 904 in X7R. The X7R parts run from 1 kV to 5 kV, with 363 at 1 kV, 242 at 2 kV, 117 at 3 kV and 84 at 5 kV.

Walsin X7R MLCC at 1 kV or more, by rated voltage Part numbers
1 kV 363
1.5 kV 41
2 kV 242
2.5 kV 19
3 kV 117
3.5 kV and 4 kV 38
5 kV 84
Total 904

By series, 496 of the 904 sit in Walsin’s middle-to-high-voltage range, 148 in the big-case series (1825, 2220, 2225), 144 in the SH soft-termination series and 84 in the S2 series, which Walsin describes as safety-certificated X1/Y2 capacitors. We have not seen this split published elsewhere. The full MLCC range lists every family.

Which Walsin parts cross a 4.7 nF, 2 kV brief?

Nineteen part numbers. We filtered the export to 4.7 nF, X7R, rated 2 kV or more, and counted 19 distinct part numbers in six case sizes, from 1210 to 2225, at 2 kV, 3 kV and 5 kV; five of them carry soft termination and three are in the S2 safety series.

The table shows the closest fits for a 4.7 nF, X7R, 2 kV, 10 percent snubber brief, plus two shelf lines that fall short on voltage. Put your incumbent in the last column.

Walsin part Series Size Rated voltage Thickness (mm) Match / mismatch with a 4.7 nF, X7R, 2 kV, 10% brief Your incumbent
1210B472K202 Middle to high voltage 1210 2 kV 2.50 Match, smallest case at 2 kV
1808B472K202 Middle to high voltage 1808 2 kV 2.00 Match
1812B472K202 Middle to high voltage 1812 2 kV 2.00 Match
1812B472K302 Middle to high voltage 1812 3 kV 2.50 Match, more voltage margin
SH43B472K202 SH soft termination 1812 2 kV 2.00 Match, soft termination
SH42B472K202 SH soft termination 1808 2 kV 2.00 Match, soft termination
2220B472K202 Big case 2220 2 kV 2.00 Match, wider creepage
S255B472K502 S2 safety, X1/Y2 2220 5 kV 2.50 Match, safety series for line-to-ground
1206B472J152 Middle to high voltage 1206 1.5 kV 1.60 Mismatch: 1.5 kV, below brief; on our shelf
1210B472K102 Middle to high voltage 1210 1 kV 1.60 Mismatch: 1 kV, below brief; on our shelf

The thickness column matters in a monitor with a tight enclosure: the 1210 part at 2 kV is 2.50 mm, taller than the 1808 and 1812 parts. Confirm against both datasheets and qualify in your own circuit.

How should a Canadian team pick case size for a 2 kV MLCC?

By creepage and board stress first, capacitance second. At 2 kV, the gap between the two terminations sets surface creepage, so an 1808 or 1812 body is easier to keep clean than a 1210, and on a large or bolted board a soft-termination SH part removes most of the flex-crack risk.

Grid equipment in Canada sees cold starts, condensation and long service lives, so contamination across the body is a real failure path. X7R capacitance also falls under DC bias, and at 2 kV the fall can be large; our note on MLCC DC bias and voltage derating explains why a snubber may need a higher nominal value than the calculation suggests. Where the capacitor bridges line to earth, use a safety-certified part such as the S2 series rather than a plain high-voltage part.

Which high voltage MLCC are on the Hong Kong shelf?

Sixty-five lines. Our stock snapshot as at 9 November 2026 holds 65 Walsin MLCC lines rated 1 kV or more, including 1206B472K102 and 1210B472K102 at 4.7 nF and 1 kV, 1812B272K202 at 2.7 nF and 2 kV, and 1808B152K302 at 1.5 nF and 3 kV.

They are on our shelf in Hong Kong (snapshot 9 Nov 2026), useful for prototypes and for checking footprint and creepage. The 2 kV, 4.7 nF parts in the table are to order: request a quote and we source them through our authorised Walsin channel. The ready-stock list is a dated snapshot, never live-synced; we confirm availability, date code and lead time on each quote and make no stock, price or delivery promise.

How Venatech helps

How Venatech helps a grid-equipment maker in Canada is a high voltage MLCC cross with every field stated. Venatech Limited, Walsin’s authorised distributor in Hong Kong, runs VenaMatch, which decodes part numbers from 18 manufacturers and crosses 800,000+ parts to Walsin, showing where each Walsin part differs from your original.

Paste your capacitor codes into the cross-reference tool, upload the whole BOM and request a quote through the site, or check the ready-stock snapshot, dated 9 November 2026. We serve Ontario, Quebec, Alberta and British Columbia from Hong Kong, in small lots with fast quotes. Walsin is the line we are authorised for; Stackpole and Viking are lines we supply. We give no customs, CSA or compliance advice; confirm that with your own team.

The short version

Evertiq reported on 13 November 2026 that Hitachi Energy will put 479 million Canadian dollars into its insulation business, with a transformer-insulation plant in London, Ontario, tied to Canada’s plan to double grid capacity by 2050. Grid equipment needs small capacitors that hold kilovolts. Walsin covers the high voltage MLCC brief with 904 X7R parts at 1 kV or more, and a 4.7 nF, 2 kV brief returns 19 part numbers in six sizes.

Send us your snubber and sensing capacitor lines, and we will return Walsin crosses with every difference stated. Which of your high-voltage positions has the tightest creepage?

Related reading

Last reviewed: 16 November 2026

Sources

Fetched 16 November 2026.

  • Evertiq, “Hitachi Energy invests over 330M in transformer insulation factory in Ontario”, 13 November 2026: https://evertiq.com/news/2026-11-13-hitachi-energy-invests-over-330m-in-transformer-insulation-factory-in-ontario
  • Walsin MLCC export, 00_ALL_MLCC_parts_combined.xlsx, re-measured 16 November 2026; Venatech stock snapshot as at 9 November 2026.

Frequently asked questions

What did Hitachi Energy announce for Canada in November 2026?

Evertiq reported on 13 November 2026 that Hitachi Energy will invest 479 million Canadian dollars in its North American insulation and components business, including a transformer-insulation plant in London, Ontario, due for completion by 2028.

What is a high voltage MLCC used for in grid equipment?

Mostly as an RC snubber across switches and relay contacts, as a coupling or filter part on voltage-sensing inputs, and in isolated gate-driver and monitor supplies. Ratings of 1 kV to 3 kV are common.

How many high voltage MLCC does Walsin offer for grid equipment in Canada?

We counted 1,874 Walsin MLCC at 1 kV or more, 904 of them X7R, rated up to 5 kV. Venatech crosses and quotes them from Hong Kong for teams in Canada.

Which Walsin part crosses a 4.7 nF 2 kV X7R capacitor?

In 1812, 1812B472K202, or SH43B472K202 with soft termination. In 1808, 1808B472K202. The smallest case is 1210B472K202, which is 2.50 mm thick. Confirm against both datasheets.

Do I need a safety-certified capacitor instead of a 2 kV MLCC?

If the capacitor bridges line to earth or across the mains, the product standard usually calls for a safety-certified type such as an X1/Y2 part. Walsin’s S2 series covers that; confirm approvals on the datasheet.

Is Venatech an authorised Walsin distributor?

Yes. Venatech Limited is an authorised Walsin distributor in Hong Kong and serves teams in Canada in small lots. Stackpole and Viking are lines we supply, not authorised lines.