Data center power consumption in the USA reached about 82 TWh a year across 403 hyperscale sites, Tom’s Hardware reported on 17 November 2026 from a Harvard-led study. Every point of PSU efficiency counts at that scale. Walsin Technology (Walsin) lists 92 C0G MLCC at 630 V and 10 nF or more. Venatech is the authorised Walsin distributor in Hong Kong.
Venatech Limited, an authorised Walsin distributor in Hong Kong, wrote this for power-supply designers, and the buyers who support them, at server PSU, power-shelf and data-center equipment makers in the USA. The study is about electricity and emissions, not components, and we draw no conclusion about any operator or supplier. The engineering link is simple: most of that electricity passes through a front-end power supply first, and the resonant stage in a modern server PSU depends on a small number of high-voltage, stable capacitors. On 18 November 2026 we re-measured Walsin’s MLCC export (Venatech_MLCC_Upload_01.xlsx to Venatech_MLCC_Upload_08.xlsx, 23,360 part numbers) against our ready-stock snapshot dated 9 November 2026.
What did the new study find about US data center power consumption?
Roughly 82 TWh in a year from 403 sites. Tom’s Hardware reported on 17 November 2026 that a Harvard-led study estimates 403 US hyperscale data centers used about 82 terawatt-hours of electricity in a year, more than 80 percent of Michigan’s entire consumption, with gas and coal supplying 54 percent of the power.
The underlying paper, “Assessing the Carbon Emissions and Energy Consumption of U.S. Hyperscale Data Centers” (arXiv 2606.05420, submitted 3 June 2026), covers May 2024 to April 2025. Its abstract gives a range of about 68 to 99 TWh across facility-load scenarios, about 1.8 percent of US electricity in the central scenario, and about 54 percent fossil generation in the attributed mix. We quote the range as well as the headline figure because the study itself presents scenarios rather than a single metered number.
Why does data center power consumption put the server power supply in focus?
Because every watt drawn passes through a conversion stage. At about 82 TWh a year, each percentage point of conversion loss across those 403 sites is of the order of 0.8 TWh, which is why power-supply designers chase fractions of a point of efficiency.
That figure is our own arithmetic on the reported total, not a number from the study, and real loss depends on where in the chain it occurs. Inside a typical server or power-shelf supply, a power-factor-correction stage feeds a high-voltage DC bus, and an LLC resonant converter steps it down. The LLC stage earns its efficiency through soft switching, and soft switching only works if the resonant frequency stays where the designer put it. That frequency is set by the resonant inductor and the resonant capacitor, so the capacitor’s value must not drift with temperature, DC bias or age. That is the job C0G dielectric does well and Class II dielectrics such as X7R do not. Our guide on MLCC DC bias and voltage derating shows how far a Class II part can move.
How many Walsin C0G MLCC reach 630 V and 10 nF?
Ninety-two part numbers. We parsed all 23,360 rows of Walsin’s MLCC export and counted 1,496 distinct C0G parts rated 630 V or more; 92 of them are also 10 nF or more, the range where most LLC resonant capacitors sit.
| Value | Part numbers | Value | Part numbers |
|---|---|---|---|
| 10 nF | 32 | 33 nF | 8 |
| 12 nF | 4 | 39 nF | 1 |
| 15 nF | 16 | 47 nF | 9 |
| 18 nF | 6 | 68 nF | 3 |
| 22 nF | 12 | 100 nF | 1 |
| Total | 92 |
By series, 32 are Soft Termination SH parts, 26 are Middle to High Voltage parts, 22 are in the big-size 1825/2220/2225 range, 10 are AEC-Q200 MT parts and 2 are AEC-Q200 soft-termination ST parts. By case, 44 are 1210 and the rest are 1206, 1812 or larger. We have not seen this cut published elsewhere. Take final values from Walsin’s WTC_MLCC_Middle_and_High_Voltage.pdf, WTC_MLCC_Soft_term_SH.pdf and WTC_MLCC_1825_2220_2225.pdf datasheets and the MLCC range, not the export alone.
Which C0G capacitor fits an LLC resonant tank in a server PSU?
One with voltage headroom for the tank swing, not just the bus. Against a brief of 22 nF to 47 nF, C0G, 630 V or more and ±5 percent, 5 of the 7 Walsin parts below match; 2 miss on value or tolerance.
| Walsin part | Case | Capacitance | Rated V | Tolerance | Series | Match / mismatch for a 22 to 47 nF, 630 V, ±5 % resonant capacitor | Your incumbent |
|---|---|---|---|---|---|---|---|
1210N333J631 |
1210 | 33 nF | 630 V | ±5 % | Middle to High Voltage | Match, smallest case at this value | |
1812N223J631 |
1812 | 22 nF | 630 V | ±5 % | Middle to High Voltage | Match | |
1210N223J102 |
1210 | 22 nF | 1,000 V | ±5 % | Middle to High Voltage | Match, more voltage headroom | |
2220N473J631 |
2220 | 47 nF | 630 V | ±5 % | Big size | Match | |
SH46N473J631 |
1825 | 47 nF | 630 V | ±5 % | Soft Termination SH | Match, flex-crack resistant termination | |
MT32N103J102 |
1210 | 10 nF | 1,000 V | ±5 % | AEC-Q200 MT | Mismatch on value; parallel two or three | |
1812N223K631 |
1812 | 22 nF | 630 V | ±10 % | Middle to High Voltage | Mismatch on tolerance |
Have part numbers to quote? Click any Walsin part number in the table to open its page and add it to your RFQ, or upload your BOM for a quote, or cross your current part in VenaMatch. E-mail sales@venatech.com.hk or call (852) 2628 4777. We confirm availability, date code and lead time on each quote.
The voltage across a resonant capacitor is the bus share plus the AC swing, and the swing rises at light load and during start-up. Check the datasheet for the AC or ripple rating at your switching frequency, not only the DC rating, and leave headroom for self-heating in a sealed PSU. Many designs split the resonant capacitance across two or more parts to spread current and heat. Our guide on middle and high voltage MLCC from 200 V to 4 kV covers the case-size trade-offs. Put your incumbent in the last column, confirm against both datasheets, and qualify in your own circuit.
Which high-voltage C0G capacitors are on the shelf in Hong Kong?
Thirty-four lines, all below 10 nF. We checked the 1,496 C0G parts at 630 V or more against our ready-stock snapshot dated 9 November 2026: 34 are on our shelf in Hong Kong, from 2.2 pF to 1,200 pF, including 1812N122J102 (1.2 nF, 1 kV) and 1206N221J102 (220 pF, 1 kV).
Those are snubber, clamp and gate-drive values rather than resonant-tank values, and they sit on the same PSU boards. On our shelf in Hong Kong (snapshot 9 November 2026) means held on that date, not a promise of quantity or date code today. The 92 parts at 10 nF or more are to order: request a quote and we source them through our authorised Walsin channel, confirming availability, date code and lead time on each quote.
How Venatech helps
How Venatech helps is a checked cross before your next PSU build. Venatech Limited, Walsin’s authorised distributor in Hong Kong, runs VenaMatch, which decodes part numbers from 18 manufacturers and crosses 800,000+ parts to Walsin, so a resonant, snubber or Y-capacitor list returns Walsin candidates with each difference stated.
Paste your capacitor part numbers into the cross-reference tool, or upload the whole PSU BOM and request a quote through the site. The ready-stock snapshot, dated 9 November 2026, lists what is on our shelf in Hong Kong. We are Hong Kong-based, ship small lots to US buyers, and confirm availability, date code and lead time on every quote. Walsin is our authorised line; Stackpole and Viking are lines we supply.
The short version
A Harvard-led study puts US hyperscale data center power consumption at about 82 TWh a year across 403 sites, Tom’s Hardware reported on 17 November 2026, within a scenario range of 68 to 99 TWh. Most of that power passes through a front-end supply, and the LLC resonant stage needs stable, high-voltage capacitors. Walsin lists 92 C0G MLCC at 630 V and 10 nF or more; 34 lower-value high-voltage C0G lines were on our Hong Kong shelf on 9 November 2026.
Send us the resonant and snubber capacitors from your current server PSU, and we will return Walsin crosses with value, voltage and case stated. Which capacitor on that board would you most like a second source for?
Related reading
- Passives for AI server power stages
- Middle and high voltage MLCC from 200 V to 4 kV
- MLCC DC bias and voltage derating
- Cross-reference tool, BOM upload and ready-stock snapshot
Last reviewed: 18 November 2026
Sources
Fetched 18 November 2026.
- Tom’s Hardware, “403 hyperscale US data centers used 82 terawatts of electricity in a year”, 17 November 2026: https://www.tomshardware.com/tech-industry/data-centers/403-hyperscale-us-data-centers-used-staggering-82-terawatts-of-electricity-in-a-year-more-than-80-percent-of-michigans-entire-consumption-generated-26-million-tons-of-co2-in-a-single-year-gas-and-coal-supplied-54-percent-of-the-power-harvard-led-study-estimates
- arXiv 2606.05420, “Assessing the Carbon Emissions and Energy Consumption of U.S. Hyperscale Data Centers”, submitted 3 June 2026: https://arxiv.org/abs/2606.05420
- Walsin MLCC export, Venatech_MLCC_Upload_01.xlsx to Venatech_MLCC_Upload_08.xlsx, re-measured 18 November 2026; Walsin datasheets WTC_MLCC_Middle_and_High_Voltage.pdf, WTC_MLCC_Soft_term_SH.pdf, WTC_MLCC_1825_2220_2225.pdf and WTC_MLCC_Automotive_MT.pdf; Venatech ready-stock snapshot dated 9 November 2026.
Frequently asked questions
<!– wp:rank-math/faq-block {"questions":[{"id":"faq-question-01","title":"How much electricity do US data centers use?","content":"Tom's Hardware reported on 17 November 2026 that a Harvard-led study estimates 403 US hyperscale data centers used about 82 TWh in a year. The paper's abstract gives a range of about 68 to 99 TWh, about 1.8 percent of US electricity.","visible":true},{"id":"faq-question-02","title":"Why use C0G instead of X7R for an LLC resonant capacitor?","content":"C0G holds its capacitance across temperature and DC bias, so the resonant frequency stays put. X7R loses capacitance under bias and heat, which shifts the operating point and can cost the efficiency the LLC stage is there to deliver.","visible":true},{"id":"faq-question-03","title":"How many Walsin C0G MLCC are rated 630 V or more?","content":"We counted 1,496 distinct Walsin C0G part numbers at 630 V or more. Ninety-two of them are 10 nF or more, from 10 nF to 100 nF, in 1206 to 2225 cases.","visible":true},{"id":"faq-question-04","title":"Is there a 33 nF 630 V C0G capacitor in 1210 for a server PSU in the USA?","content":"Yes.1210N333J631 is 33 nF, 630 V, C0G, ±5 percent in 1210, in Walsin’s Middle to High Voltage series. Confirm the AC rating at your switching frequency on the datasheet.”,”visible”:true},{“id”:”faq-question-05″,”title”:”Are high-voltage C0G capacitors in stock in Hong Kong?”,”content”:”Thirty-four C0G lines at 630 V or more were on our shelf in Hong Kong in the snapshot dated 9 November 2026, all below 10 nF. We source the higher values through our authorised Walsin channel.”,”visible”:true},{“id”:”faq-question-06″,”title”:”Is Venatech an authorised Walsin distributor for buyers in the USA?”,”content”:”Venatech Limited is an authorised Walsin distributor in Hong Kong and supplies US buyers in small lots. Stackpole and Viking are lines we supply, not authorised lines.”,”visible”:true}],”listStyle”:””,”titleWrapper”:”h3″,”titleCssClasses”:””,”contentCssClasses”:””,”sizeSlug”:””} –>
How much electricity do US data centers use?
Tom’s Hardware reported on 17 November 2026 that a Harvard-led study estimates 403 US hyperscale data centers used about 82 TWh in a year. The paper’s abstract gives a range of about 68 to 99 TWh, about 1.8 percent of US electricity.
Why use C0G instead of X7R for an LLC resonant capacitor?
C0G holds its capacitance across temperature and DC bias, so the resonant frequency stays put. X7R loses capacitance under bias and heat, which shifts the operating point and can cost the efficiency the LLC stage is there to deliver.
How many Walsin C0G MLCC are rated 630 V or more?
We counted 1,496 distinct Walsin C0G part numbers at 630 V or more. Ninety-two of them are 10 nF or more, from 10 nF to 100 nF, in 1206 to 2225 cases.
Is there a 33 nF 630 V C0G capacitor in 1210 for a server PSU in the USA?
Yes. 1210N333J631 is 33 nF, 630 V, C0G, ±5 percent in 1210, in Walsin’s Middle to High Voltage series. Confirm the AC rating at your switching frequency on the datasheet.