An X6S MLCC is rated from minus 55 to plus 105 °C, 20 degrees above X5R, which matters on hot AI server boards. Walsin lists 125 X6S capacitors, 88 of them at 1 µF or more, from 0201 to 1210. Venatech is the authorised Walsin distributor in Hong Kong.
Venatech Limited, an authorised Walsin distributor in Hong Kong, wrote this for power and hardware engineers, and the buyers behind them, at AI server, rack and motherboard makers in Taoyuan, from Daxi and Guishan to Luzhu and Zhongli. Walsin Technology (Walsin) is the line we are authorised for. On 19 November 2026 we parsed our eight MLCC upload files, Venatech_MLCC_Upload_01.xlsx to Venatech_MLCC_Upload_08.xlsx, and counted distinct part numbers by dielectric, size, voltage and capacitance, reading the X6S and X5R rows against Walsin’s WTC_MLCC_General_Purpose.pdf datasheet. Every part number below is real.
What did Compal open in Daxi, Taoyuan?
An AI server manufacturing centre. Evertiq reported on 19 August 2026 that Compal opened its Daxi AI Server Manufacturing Center in Taoyuan, an investment of 4.03 billion New Taiwan dollars on about 21,700 square metres, expected to double Compal’s AI server production capacity, with revenue contributions from the fourth quarter of 2026.
The same report says the centre builds AI server systems and rack-level products at the L10 and L11 integration levels, using Compal’s own liquid-cooling technology for high-density AI infrastructure. We quote nothing beyond that. For engineers in Taoyuan the hook is the board, not the building: accelerator baseboards and server motherboards carry thousands of MLCC around voltage regulators and processors, many of them in places where the local temperature is well above the air coming into the chassis. That is where the dielectric’s upper temperature limit stops being a footnote.
Why does an AI server board need an X6S MLCC instead of X5R?
Temperature headroom. X5R is specified to plus 85 °C and X6S to plus 105 °C, both class II dielectrics; X6S allows a ±22 percent capacitance change over its range against ±15 percent for X5R, so you trade a little stability for 20 degrees of rating.
A decoupling capacitor tucked beside a multiphase regulator or under a liquid-cooled accelerator may not see the coolant temperature; it sees the copper around it, the inductors next to it and its own ripple-current heating. If a thermal survey of the board puts a capacitor position above 85 °C, an X5R part is outside its rating there, however good its capacitance looks on paper. X6S keeps the same small cases and the same high capacitance per case as X5R, which is why it shows up on dense power stages. X7R goes to 125 °C but reaches less capacitance per case. Our post on passives for AI server power stages covers the rest of the stage.
How many X6S MLCC does Walsin list, and in which sizes?
- We counted 125 distinct X6S part numbers in Walsin’s general purpose family, against 723 X5R parts; 88 of the X6S parts are 1 µF or more, and three X6S lines are on our shelf in Hong Kong (snapshot 9 Nov 2026).
| Walsin X6S MLCC, by case size | Parts | Example at the high end |
|---|---|---|
| 0201 | 29 | 0201S105M6R3, 1 µF, 6.3 V |
| 0402 | 30 | 0402S106M6R3, 10 µF, 6.3 V |
| 0603 | 23 | 0603S226M6R3, 22 µF, 6.3 V |
| 0805 | 20 | 0805S476M6R3, 47 µF, 6.3 V |
| 1206 | 11 | 1206S107M4R0, 100 µF, 4 V |
| 1210 | 12 | 1210S107M6R3, 100 µF, 6.3 V |
| Total | 125 |
Have part numbers to quote? Click any Walsin part number in the table to open its page and add it to your RFQ, or upload your BOM for a quote, or cross your current part in VenaMatch. E-mail sales@venatech.com.hk or call (852) 2628 4777. We confirm availability, date code and lead time on each quote.
By rated voltage, 24 are 4 V, 35 are 6.3 V, 29 are 10 V, 17 are 16 V, 16 are 25 V, and the remaining four are 35, 50 and 100 V parts. That spread fits server rails: core and memory rails run at around 1 V or below, and 4 to 6.3 V parts give room above them. We have not seen Walsin’s X6S range laid out by size and voltage anywhere else.
Which Walsin parts fit a 10 µF, 0603, 105 °C decoupling brief?
Three fit. For 10 µF, 0603, at least 6.3 V and rated to 105 °C, 0603S106M6R3, 0603S106M100 and 0603S106M160 match; the X5R parts with the same value and case stop at 85 °C, even though four of them are on our shelf in Hong Kong (snapshot 9 Nov 2026).
| Brief: 10 µF, 0603, ≥ 6.3 V, rated to 105 °C | Walsin part | Dielectric | Match / mismatch | Your incumbent |
|---|---|---|---|---|
| Direct fit | 0603S106M6R3 |
X6S | Match, 6.3 V, ±20% | |
| More voltage | 0603S106M100 |
X6S | Match, 10 V, ±20% | |
| More voltage | 0603S106M160 |
X6S | Match, 16 V, ±20% | |
| Lower voltage | 0603S106M4R0 |
X6S | Mismatch in voltage (4 V) | |
| Same value, on the shelf | 0603X106M6R3 |
X5R | Mismatch in temperature (85 °C) | |
| Same value, ±10%, on the shelf | 0603X106K6R3 |
X5R | Mismatch in temperature (85 °C) | |
| Smaller case | 0402S106M6R3 |
X6S | Mismatch in size (0402) |
The export holds 12 Walsin parts at 10 µF in 0603: eight X5R and four X6S. Leave the last column for your current part, and check the rated temperature column of the incumbent’s datasheet, not only its value and voltage.
How much capacitance does an X6S MLCC keep under DC bias?
Less than its label, like every class II part. A 10 µF X6S or X5R capacitor in 0603 can lose a large share of its capacitance at its rated voltage; choosing a 10 V or 16 V part for a 1 V rail, as two of the three matches allow, keeps the bias well below rating and the effective capacitance higher.
The temperature code says nothing about DC bias. Both X5R and X6S use ferroelectric ceramics whose permittivity falls as the field across the dielectric rises, and the smaller the case for a given capacitance, the thinner the layers and the steeper the fall. On a server board that usually means two things: pick the highest voltage rating that fits the footprint, and count effective, not nominal, capacitance when you size the bank under an accelerator. Our post on MLCC DC bias and voltage derating shows how to read the curves.
Check the datasheet. The export lists value, voltage and temperature range but no DC bias curve. Take the curve for each case and voltage from WTC_MLCC_General_Purpose.pdf, or ask us for Walsin’s characteristic data, before you fix the number of capacitors in a bank.
How Venatech helps: what can we supply to a Taoyuan server line?
The decoupling bank and the rest of the passives list, crossed in one pass. Venatech is the authorised Walsin distributor in Hong Kong; VenaMatch decodes part numbers from 18 manufacturers and crosses 800,000+ parts to Walsin, including all 125 Walsin X6S and 723 X5R capacitors counted above.
Paste your MLCC lines into the cross-reference tool, upload the board’s BOM at /bom/, or check the dated ready stock list. Three X6S lines, among them 0402S105K6R3 (1 µF, 0402, 6.3 V), are on our shelf in Hong Kong (snapshot 9 Nov 2026); for the 10 µF X6S parts, request a quote and we source them through our authorised Walsin channel. We serve Taiwan from Hong Kong in small lots, which suits engineering builds, and we quote fast. We confirm availability, date code and lead time on each quote and promise none in advance; qualification stays with your engineers, and import questions with your compliance team. The MLCC range page lists every family.
The short version
- Compal opened its Daxi AI Server Manufacturing Center in Taoyuan, 4.03 billion New Taiwan dollars and about 21,700 square metres, expected to double its AI server capacity (Evertiq, 19 August 2026).
- X6S is rated to 105 °C, 20 degrees above X5R; Walsin lists 125 X6S MLCC, 88 at 1 µF or more.
- For 10 µF, 0603, 105 °C, 0603S106M6R3, 0603S106M100 and 0603S106M160 match.
- Pick the highest voltage that fits, and size the bank on effective capacitance.
Send us the decoupling lines from your accelerator or motherboard BOM and we will return the Walsin X6S crosses with every difference stated. Which of your capacitor positions runs above 85 °C?
Related reading
- Passives for AI server power stages
- Reading a GPU VRM power stage as a shopping list
- MLCC DC bias and voltage derating
- Cross-reference tool, BOM upload and ready stock snapshot
Last reviewed: 19 November 2026.
Sources
Fetched 19 November 2026.
- Evertiq, Compal opens AI server manufacturing centre in Taoyuan, 19 August 2026: https://evertiq.com/news/2026-08-19-compal-opens-ai-server-manufacturing-centre-in-taoyuan
- Venatech MLCC upload files Venatech_MLCC_Upload_01.xlsx to _08.xlsx and Walsin’s WTC_MLCC_General_Purpose.pdf datasheet as linked in the export, re-measured 19 November 2026; Venatech ready stock snapshot dated 9 November 2026.
Frequently asked questions
How many X6S MLCC does Walsin make?
125 distinct part numbers in our count of 19 November 2026, from 0201 to 1210 and 4 V to 100 V; 88 are 1 µF or more.
Which Walsin part is a 10 µF, 0603, X6S capacitor?
0603S106M6R3 at 6.3 V, 0603S106M100 at 10 V or 0603S106M160 at 16 V, all ±20 percent and rated to 105 °C. 0603S106M4R0 is the 4 V version.
What is the difference between X6S and X5R?
X5R is rated to plus 85 °C with ±15 percent change; X6S is rated to plus 105 °C with ±22 percent. Both are class II and both lose capacitance under DC bias.
Can I replace an X5R capacitor with an X6S part?
Usually yes when value, case and voltage line up, since X6S covers a wider temperature range. Compare DC bias and tolerance in both datasheets and qualify on your board.
Does Venatech stock X6S capacitors for Taiwan?
We hold stock in Hong Kong: three Walsin X6S lines are on our shelf in Hong Kong (snapshot 9 Nov 2026). The 10 µF X6S parts are quoted through our authorised Walsin channel.
Can Venatech supply AI server makers in Taoyuan, Taiwan?
Yes. Venatech is the authorised Walsin distributor in Hong Kong and quotes small lots to Taiwan. Use the cross-reference tool or upload a BOM; confirm import rules with your compliance team.