NEWS

100V MLCC for 48 V Data Centre Power in Batam, Indonesia: DayOne’s 450 MW Kabil Campus and 250 Walsin 100 V Capacitors at 100 nF or More

A 48 V rack bus runs close to 60 V at its peak, so its ceramics are usually specified at 100 V. Walsin lists 250 class II 100V MLCC at 100 nF or more, 13 of them on our shelf in Hong Kong (snapshot 9 Nov 2026). Venatech is the authorised Walsin distributor in Hong Kong.


Venatech Limited, an authorised Walsin distributor in Hong Kong, wrote this for power and hardware engineers, and their buyers, at rack power, server and EMS makers building for Batam’s data centre campuses and the Riau Islands. Walsin Technology (Walsin) is the line we are authorised for. On 20 November 2026 we parsed our eight MLCC upload files, Venatech_MLCC_Upload_01.xlsx to Venatech_MLCC_Upload_08.xlsx, kept the parts rated 100 V, and counted distinct part numbers by dielectric, capacitance, size and series, reading them against Walsin’s WTC_MLCC_General_Purpose.pdf, WTC_MLCC_Automotive_MT.pdf and WTC_MLCC_Soft_term_SH.pdf datasheets. Every part number below is in that export.

What is DayOne building at Kabil in Batam?

A 450 MW hyperscale campus. The Jakarta Post reported on 20 April 2026 that BP Batam, the state utility PLN and DayOne signed an electricity purchase agreement for DayOne’s second hyperscale data centre in Batam, a 450 megawatt facility at Kabil Industrial Tech Park, with supply phased in over 2026 and 2027.

The report describes the site as built for AI and cloud computing for the Asia-Pacific region, and says it would reportedly be the largest data centre customer in Indonesia; DayOne’s first Batam project is at Nongsa Digital Park. We quote nothing beyond that. What a campus on this scale brings is power hardware: transformers and switchgear at the site level, and inside the halls, rack power shelves, busbars and server boards that increasingly distribute power at 48 V rather than 12 V. Every one of those boards carries ceramic capacitors on the 48 V input, and most of them are specified at 100 V.

Why does a 48 V rack bus need a 100V MLCC?

Margin over the bus. A nominal 48 V bus is usually allowed to range up to about 54 to 60 V, so a 50 V capacitor has almost no headroom, and the common practice is to step up to the next standard rating, 100 V, which leaves the part running at roughly half its rated voltage.

Three things push the choice. The bus itself moves with load and battery state. Hot-plug and load steps add transients on top of it. And class II ceramics such as X7R lose capacitance as DC voltage rises, so a part running near its rating delivers less of its nominal value. A 100 V part on a 48 V bus addresses all three at once. It also gives the buyer a simple rule to check on every input line of the BOM: anything on the 48 V side that is not at least 100 V deserves a second look. Our post on MLCC DC bias and voltage derating covers the general case.

How many 100 V MLCC at 100 nF or more does Walsin list?

  1. We counted 3,084 distinct Walsin MLCC rated 100 V; 250 of them are class II parts at 100 nF or more, and 86 of those reach 1 µF or more, up to 22 µF in the large case sizes.
Walsin 100 V class II MLCC at ≥ 100 nF, by size Parts
0603 8
0805 27
1206 68
1210 61
1812 47
1825 3
2220 30
2225 6
Total 250

By series, 119 are general purpose parts, 44 are SH soft-termination parts, 36 are large-size parts, 20 are AEC-Q200 MT parts, 19 are AEC-Q200 ST soft-termination parts and 9 are MG automotive parts without AEC-Q200; the rest are two SG soft-termination parts and one low-profile part. Of the 3,084 parts at 100 V, 2,163 are C0G, which are useful for snubbers and timing on the same board but carry far less capacitance per case.

Which Walsin parts cross a 1 uF, 100 V X7R brief?

Several, and two are on our shelf. For 1 µF, 100 V, X7R and ±10 percent, 1206B105K101 and 1210B105K101 match and are on our shelf in Hong Kong (snapshot 9 Nov 2026); AEC-Q200, soft-termination and larger-case versions are also listed.

Brief: 1 µF, 100 V, X7R, ±10% Walsin part Size Series Match / mismatch Your incumbent
General purpose, on the shelf 1206B105K101 1206 General purpose Match
General purpose, on the shelf 1210B105K101 1210 General purpose Match, larger case
Automotive MT31B105K101 1206 MT, AEC-Q200 Match, adds AEC-Q200
Soft termination SH31B105K101 1206 SH, Ag-polymer Match, adds flex crack protection
Larger case 1812B105K101 1812 General purpose Match, larger case
Smaller case 0805A105K101 0805 General purpose Mismatch in dielectric (X7S)

Have part numbers to quote? Click any Walsin part number in the table to open its page and add it to your RFQ, or upload your BOM for a quote, or cross your current part in VenaMatch. E-mail sales@venatech.com.hk or call (852) 2628 4777. We confirm availability, date code and lead time on each quote.

The 0805 row is the trap. It saves board area but is listed as X7S, not X7R, and a smaller case at the same voltage generally loses more capacitance under bias. Leave the last column for the part on your current BOM. Our post on MLCC DC bias derating and the empty export columns explains why the export cannot settle this on its own.

Does DC bias change the choice at 48 V?

Yes, it often decides the case size. Running at 48 V puts a 100 V X7R part at about half its rating, where class II ceramics lose part of their capacitance, and that loss generally grows as the case gets smaller, so a 1210 can keep more of its 1 µF than a 1206.

The export does not carry DC bias data, so do not size from it. Read the bias curve for the exact series and case in WTC_MLCC_General_Purpose.pdf, or ask us for the datasheet page. Two other points matter on rack power boards. Large ceramic cases on a thick board flex during depanelling, screwing down and thermal cycling; the SH soft-termination parts exist for that. And if the shelf or busbar sits near a fan or hot-swap connector, put the extra margin into the capacitor count, not into a higher-voltage part that the line has never qualified.

Check the datasheet. The 1 µF 100 V parts above share a value and rating but not a thickness; the export lists 1.60 mm for the 1206 parts and 2.00 mm for the 1210 and 1812 parts. Confirm height against your keep-out before you switch cases.

How Venatech helps: what can we supply to Batam power and server builds?

The ceramic capacitors on a rack power BOM, crossed and partly held in stock. Venatech is the authorised Walsin distributor in Hong Kong; VenaMatch decodes part numbers from 18 manufacturers and crosses 800,000+ parts to Walsin, including all 250 of the 100 V capacitors counted above.

Paste your input-side capacitor lines into the cross-reference tool, upload the board’s BOM at /bom/, or check the dated ready stock list. We checked all 250 against our snapshot: thirteen are on our shelf in Hong Kong (snapshot 9 Nov 2026), among them 1206B105K101, 1210B105K101, 1210B334K101 and 2220B474K101; for the rest, request a quote and we source them through our authorised Walsin channel. We serve Batam from Hong Kong in small lots for pilot and NPI builds; we confirm availability, date code and lead time on each quote and promise none in advance. Qualification stays with your engineers, and import questions with your compliance team. The MLCC range page lists every series.

The short version

  • BP Batam, PLN and DayOne signed a power deal for a 450 MW hyperscale data centre at Kabil Industrial Tech Park, with supply phased in over 2026 and 2027 (The Jakarta Post, 20 April 2026).
  • A 48 V bus ranges up to about 60 V, so its ceramics are usually specified at 100 V.
  • Walsin lists 3,084 MLCC at 100 V; 250 are class II at 100 nF or more, and 86 reach 1 µF.
  • For 1 µF, 100 V X7R, 1206B105K101 and 1210B105K101 match and are on our shelf; the 0805 option is X7S.

Send us the 48 V side of your next power board and we will return Walsin crosses with case, dielectric and shelf status stated. How much of your nominal 1 µF is left at 54 V?

Related reading

Last reviewed: 20 November 2026.

Sources

Fetched 20 November 2026.

  • The Jakarta Post, BP Batam, PLN sign deal to power city’s second hyperscale data center, 20 April 2026: https://www.thejakartapost.com/business/2026/04/20/bp-batam-pln-sign-deal-to-power-citys-second-hyperscale-data-center
  • Venatech MLCC upload files Venatech_MLCC_Upload_01.xlsx to _08.xlsx and Walsin’s WTC_MLCC_General_Purpose.pdf, WTC_MLCC_Automotive_MT.pdf, WTC_MLCC_Soft_term_SH.pdf and WTC_MLCC_1825_2220_2225.pdf datasheets as linked in the export, re-measured 20 November 2026; Venatech ready stock snapshot dated 9 November 2026.

Frequently asked questions

What voltage MLCC do I need on a 48 V bus?

100 V is the usual choice. A 48 V bus ranges up to about 54 to 60 V, which leaves a 50 V part almost no margin and puts a 100 V part near half its rating.

How many 100V MLCC does Walsin make?

3,084 in our count of 20 November 2026. 250 are class II parts at 100 nF or more and 86 of those reach 1 µF or more.

Which Walsin part is a 1 uF 100 V X7R 1206 capacitor?

1206B105K101 in the general purpose series, MT31B105K101 in the AEC-Q200 MT series and SH31B105K101 with soft termination.

Is 0805A105K101 a drop-in match for a 1 uF 100 V X7R part?

No. It has the value and voltage but is listed as X7S, and a smaller case generally keeps less capacitance at 48 V. Check the datasheet bias curve first.

Does Venatech stock 100 V MLCC for Indonesia?

Thirteen Walsin 100 V class II MLCC at 100 nF or more are on our shelf in Hong Kong (snapshot 9 Nov 2026), including 1206B105K101 and 1210B105K101. Others are quoted through our authorised Walsin channel.

Can Venatech supply data centre hardware makers in Batam, Indonesia?

Yes. Venatech is the authorised Walsin distributor in Hong Kong and quotes small lots to Batam. Use the cross-reference tool or upload a BOM; confirm import rules with your compliance team.


Share This, Choose Your Platform!