C0G Capacitor for Medical Devices in Tijuana, Mexico: 2,994 Walsin 0402 C0G MLCC up to 1 nF

A C0G capacitor holds its value with temperature and voltage and makes no microphonic noise, so medical signal chains rely on it. Walsin lists 2,994 C0G MLCC in 0402, from 0.05 pF to 1 nF. Venatech is the authorised Walsin distributor in Hong Kong and supplies them to Mexico.


Venatech Limited, an authorised Walsin distributor in Hong Kong, wrote this for electronics design, component and supplier-quality engineers and buyers at medical device makers and contract manufacturers in Tijuana and across Baja California. Walsin Technology (Walsin) is the line we are authorised for. On 19 November 2026 we parsed our eight MLCC upload files, Venatech_MLCC_Upload_01.xlsx to Venatech_MLCC_Upload_08.xlsx, and counted distinct C0G part numbers in the 0402 case, reading them against Walsin’s datasheets WTC_MLCC_General_Purpose.pdf, WTC_MLCC_Automotive_MT.pdf and WTC_MLCC_Soft_term_SH.pdf. Every part number below is real.

How big is medical device manufacturing in Tijuana in 2026?

Big enough to be its own corridor. The Tijuana Economic Development Corporation wrote on 4 June 2026 that Tijuana has 73 active medical device manufacturing facilities, that Baja California’s medical device companies employ more than 74,000 people, and that the sector exports about 3.2 billion US dollars a year, 88 percent of it to US manufacturers.

The work is moving up the chain. Mexico Industry reported on 17 September 2026 that the Baja California medical device cluster announced plans for a medical device innovation and development centre in Tijuana, to add design, engineering and research to the region’s manufacturing. Neither source names components, so we name none of any maker’s parts. For a component engineer the direction matters: more boards are being designed, not only built, in Tijuana, and design choices such as the capacitor dielectric are made locally.

Why do medical device front ends use a C0G capacitor?

Because it does not move. A C0G capacitor changes by no more than about 30 ppm per degree Celsius and does not lose capacitance under DC bias, while Class II dielectrics such as X7R drift with temperature and voltage and are piezoelectric, so they can turn vibration into signal noise.

That combination matters in the low-level analogue paths of patient monitors, infusion pump sensors, ECG and EEG front ends, pulse oximeters and diagnostic analysers. Anti-aliasing and RFI filters in front of an instrumentation amplifier or ADC need capacitors whose value is set by the design, not by the room temperature or the bias on the line, and a piezoelectric capacitor near a pump motor or a fan can add noise in exactly the band being measured. Our guide to NP0 vs X7R vs X5R explains the codes, and passives for a medical device covers the wider board.

Check the datasheet. The positions above are typical of medical signal chains, not taken from any Tijuana maker’s design. Walsin’s datasheets give the C0G temperature characteristic and the application conditions; confirm suitability for your device class with your own quality and regulatory team.

How many 0402 C0G capacitors does Walsin list?

2,994. We counted 2,994 distinct Walsin C0G MLCC in the 0402 case, from 0.05 pF to 1 nF, in eight series; 1,386 of them are rated 50 V. 1 nF is the highest C0G value Walsin lists in 0402.

0402 C0G series Parts Typical use
General Purpose Caps 1,030 Filters, timing, signal coupling
Microwave Caps (RF series) 908 RF matching, wireless modules
High Q and Low ESR (HH series) 508 RF and high-frequency filters
Automotive, AEC-Q200 (MT series) 279 Harsh-environment boards
Automotive, without AEC-Q200 (MG series) 105 Automotive-grade process
Ultra Microwave (UF series) 79 Very low values for RF
Middle to High Voltage 44 200 V and 250 V positions
Soft termination (SH series) 41 Boards that flex
Total 2,994

By voltage the 2,994 split 1,386 at 50 V, 517 at 25 V, 415 at 100 V, 289 at 16 V, 196 at 200 V, 170 at 10 V, 20 at 250 V and one at 6.3 V. Across all sizes Walsin lists 15,133 C0G parts, so the 0402 case holds about one in five. We have not seen Walsin’s 0402 C0G range broken out by series this way anywhere else.

Which Walsin parts cross a 1 nF, 0402, 50 V C0G capacitor brief?

Four fit. For 1 nF, 0402, C0G, ±5 percent and at least 50 V, 0402N102J500 matches, 0402N102F500 matches at ±1 percent, and the AEC-Q200 MT15N102J500 and soft termination SH15N102J500 match too; the 25 V part and the 470 pF part miss on one field.

Brief: 1 nF, 0402, C0G, ±5%, ≥ 50 V Walsin part Series Match / mismatch Your incumbent
Direct fit 0402N102J500 General Purpose Match, on our shelf
Tighter tolerance 0402N102F500 General Purpose Match, ±1%, on our shelf
Automotive grade MT15N102J500 MT, AEC-Q200 Match
Flex-tolerant SH15N102J500 SH soft termination Match, thickness tolerance ±0.20 mm
Lower voltage 0402N102J250 General Purpose Mismatch in voltage (25 V)
Wrong value 0402N471J500 General Purpose Mismatch in value (470 pF)

Have part numbers to quote? Click any Walsin part number in the table to open its page and add it to your RFQ, or upload your BOM for a quote, or cross your current part in VenaMatch. E-mail sales@venatech.com.hk or call (852) 2628 4777. We confirm availability, date code and lead time on each quote.

Leave the last column for your current part. In an RC filter that sets a corner frequency, the ±1 percent part tightens the spread between channels; in a simple RFI shunt, ±5 percent is usually enough.

Should a medical board use AEC-Q200 or soft termination C0G parts?

Only where the board needs it. Walsin lists 279 AEC-Q200 C0G parts in 0402 in the MT series and 41 soft termination C0G parts in the SH series; both add assurance for harsh or flexing boards, and neither changes the C0G dielectric itself.

A portable or wearable device that is dropped, flexed or cycled through sterilisation temperatures may justify the SH soft termination, which adds a flexible layer under the terminations to resist cracking. A device whose supplier-quality plan already references AEC-Q200 test data may prefer the MT series for that documentation. On the shelf, 95 Walsin 0402 C0G parts are on our shelf in Hong Kong (snapshot 9 Nov 2026), 67 of them General Purpose, including 0402N102J500 and 0402N102F500. The MT and SH parts above are to order: request a quote and we source them through our authorised Walsin channel. The MLCC range page lists every series.

How Venatech helps: what can we supply to a medical device maker in Tijuana?

The capacitors and resistors of the whole signal chain, crossed in one pass. Venatech is the authorised Walsin distributor in Hong Kong; VenaMatch decodes part numbers from 18 manufacturers and crosses 800,000+ parts to Walsin, including all 2,994 Walsin 0402 C0G MLCC.

Paste your filter and decoupling lines into the cross-reference tool, upload the BOM at /bom/, or see the dated ready stock list. We serve Mexico from Hong Kong in small lots, which suits design builds, verification lots and pilot runs, and you can request a quote for any line through the site. We confirm availability, date code and lead time on each quote and promise none in advance; qualification and regulatory decisions stay with your engineers, and import questions with your compliance team.

The short version

  • Tijuana has 73 active medical device plants, and Baja California’s medical device sector exports about 3.2 billion US dollars a year (Tijuana EDC, 4 June 2026).
  • Walsin lists 2,994 C0G MLCC in 0402, from 0.05 pF to 1 nF; 1,386 are rated 50 V.
  • For a 1 nF, 0402, 50 V brief, 0402N102J500 and 0402N102F500 match and are on our shelf in Hong Kong (snapshot 9 Nov 2026).
  • MT15N102J500 adds AEC-Q200; SH15N102J500 adds soft termination.

Send us the filter capacitors from your medical front end and we will return the Walsin crosses with every difference stated. Is there an X7R part in your signal path that should be C0G?

Related reading

Last reviewed: 19 November 2026.

Sources

Fetched 19 November 2026.

  • Tijuana Economic Development Corporation, Cali Baja biomedical manufacturing corridor: 8 key facts, 4 June 2026: https://tijuanaedc.org/cali-baja-biomedical-manufacturing-corridor-8-key-facts/
  • Mexico Industry, Tijuana proyecta centro de innovación para llevar industria médica hacia diseño e I+D, 17 September 2026: https://mexicoindustry.com/noticia/tijuana-proyecta-centro-de-innovacion-para-llevar-industria-medica-hacia-diseno-e-i-d
  • Venatech MLCC upload files Venatech_MLCC_Upload_01.xlsx to _08.xlsx and Walsin’s WTC_MLCC_General_Purpose.pdf, WTC_MLCC_Automotive_MT.pdf and WTC_MLCC_Soft_term_SH.pdf datasheets as linked in the export, re-measured 19 November 2026; Venatech ready stock snapshot dated 9 November 2026.

Frequently asked questions

What is a C0G capacitor?

A Class I ceramic capacitor whose value changes by no more than about 30 ppm per degree Celsius and does not fall under DC bias. C0G and NP0 name the same characteristic.

How many 0402 C0G capacitors does Walsin make?

2,994 in our count of 19 November 2026, from 0.05 pF to 1 nF, in eight series; 1,386 are rated 50 V.

Which Walsin part is a 1 nF, 0402, 50 V C0G capacitor?

0402N102J500 at ±5 percent or 0402N102F500 at ±1 percent. MT15N102J500 is the AEC-Q200 option and SH15N102J500 the soft termination option.

Why avoid X7R in a medical signal path?

X7R drifts with temperature and DC bias and is piezoelectric, so vibration can show up as noise. C0G avoids all three.

Does Venatech stock C0G capacitors for Mexico?

We hold stock in Hong Kong. 95 Walsin 0402 C0G parts are on our shelf in Hong Kong (snapshot 9 Nov 2026), including 0402N102J500; the rest are quoted through our authorised Walsin channel.

Can Venatech supply medical device makers in Tijuana, Mexico?

Yes. Venatech is the authorised Walsin distributor in Hong Kong and quotes small lots to Mexico. Use the cross-reference tool or upload a BOM; confirm import rules with your compliance team.