NEWS

01005 Capacitor for Medical Wearables in Switzerland: Cicor and CSEM Team Up on Wearable Health Devices, and 608 Walsin 01005 MLCC

Swiss EMS provider Cicor and technology centre CSEM have teamed up to take wearable health devices into series production, Evertiq reported on 16 November 2026. Wearables push passives down to the 01005 capacitor. Walsin Technology (Walsin) lists 608 MLCC in 01005, and 65 of our 100 shelf 0201 lines have an 01005 twin. Venatech is the authorised Walsin distributor in Hong Kong.


A wearable health sensor is mostly battery, antenna and enclosure; the electronics get whatever space is left. That is why medical wearable boards are among the first in Switzerland to use 01005 parts, at the small end of what production lines place today. We wrote this for the layout and industrialisation engineers in Switzerland who are taking such devices from prototype to series build, and for the buyers who will source the parts. The partnership names no component suppliers, and we make no claim about any device it will produce. On 21 November 2026 we parsed Walsin’s MLCC export (Venatech_MLCC_Upload_01.xlsx to Venatech_MLCC_Upload_08.xlsx) for its 01005 range, which Walsin codes as 01R5, and checked our 0201 shelf against it.

What did Cicor and CSEM agree in Switzerland?

A partnership on medical wearables. Evertiq reported on 16 November 2026 that Cicor, a Swiss electronics manufacturing services provider, and CSEM, a Swiss technology centre, will work together to move wearable health monitoring, vital-signs sensing and connected medical devices from concept to series production.

According to the report, CSEM brings vital-signs sensing technologies and algorithms for health, wellness and sports, while Cicor brings product development, system integration, industrialisation and manufacturing of medical electronics and complete devices. The partnership is non-exclusive, and projects run from feasibility studies and prototypes to industrialisation, agreed one customer at a time. No figures or timelines were given. For the supply chain, the point is that Swiss wearable projects are being set up for series production, which is where part selection is frozen and second sources start to matter.

Why do medical wearables move from 0201 to the 01005 capacitor?

Because each 01005 part takes less than half the board area. An 01005 capacitor measures 0.40 x 0.20 mm against 0.60 x 0.30 mm for 0201, about 56 % less area per part, which on a wearable with a hundred or more passives can free space for a larger battery or a better antenna.

The saving comes with costs. Placement needs finer nozzles and tighter paste control, rework is harder, and inspection must resolve smaller fillets. Electrically, the smaller body holds less capacitance at a given rating and usually a lower rated voltage. For a wearable running from a single cell, the voltage limit rarely bites, but capacitance under DC bias still does. Our guide to Walsin ultra-small MLCC in 01R5 and 01005 explains the naming, and passives for a medical device covers the documentation side.

How many Walsin 01005 capacitors are there, and what do they cover?

Six hundred and eight. We counted 608 distinct Walsin MLCC part numbers in the 01005 (01R5) case: 317 in the ultra-small 01R5 series and 291 in the microwave RF series, with 567 in C0G, 32 in X5R and 9 in X7R.

The C0G parts run from 0.2 pF to 220 pF, which covers RF matching and timing. The X5R parts reach 100 nF, and the X7R parts reach 1 nF. By rating, 275 are 16 V and 259 are 25 V, with 30 at 50 V and 44 at 10 V or below. That makes the range strong for radio front ends and small-signal filtering, and thinner for bulk decoupling, which in a wearable usually stays in 0201 or 0402. The MLCC range page links each series datasheet.

Which 0201 capacitors on our shelf have an 01005 twin?

Sixty-five of one hundred. We checked the 100 distinct 0201 MLCC lines on our shelf in Hong Kong (snapshot 9 November 2026) against the 01005 range: 65 have a twin with the same dielectric, capacitance and tolerance, and 28 of those also keep the rated voltage.

Shelf part (0201) Value, rating 01005 twin Match / mismatch
0201X104K6R3 100 nF X5R 6.3 V 01R5X104K6R3 Match on all four fields
0201X683K6R3 68 nF X5R 6.3 V 01R5X683K6R3 Match on all four fields
0201B101K160 100 pF X7R 16 V 01R5B101K100 Mismatch on voltage: twin is 10 V
0201N101J500 100 pF C0G 50 V 01R5N101J160 Mismatch on voltage: twin is 16 V
0201N1R5B500 1.5 pF C0G 50 V RF02N1R5B160 Mismatch on voltage; RF series twin, 16 V
0201B103K6R3 10 nF X7R 6.3 V none in X7R Mismatch: X7R stops at 1 nF in 01005
0201B472K100 4.7 nF X7R 10 V none in X7R Mismatch: keep 0201 or move to X5R

Have part numbers to quote? Click any Walsin part number in the table to open its page and add it to your RFQ, or upload your BOM for a quote, or cross your current part in VenaMatch. E-mail sales@venatech.com.hk or call (852) 2628 4777. We confirm availability, date code and lead time on each quote.

Most of the 37 voltage mismatches are 50 V C0G parts whose 01005 twin is rated 16 V or 25 V; in a battery-powered wearable that rarely matters, but confirm it against the highest voltage on the net. The 01005 twins are supplied to order through our authorised Walsin channel.

What should a Swiss wearable team check before moving to 01005?

Three things, in this order. Before a wearable board in Switzerland moves to the 01005 capacitor, check that the EMS line can place and inspect 01005 at volume, read each twin’s DC-bias and voltage rating, and confirm the change against the device’s design file.

Assembly comes first: ask the EMS partner for its 01005 placement and inspection record, not only its capability list. Electrical behaviour comes second, part by part, from the datasheet; a matched code does not guarantee matched capacitance under bias. Documentation comes third. A medical device’s design history records its parts, and any change to a released design belongs to your regulatory team to assess. We give no regulatory advice; Swiss and EU medical-device requirements are for your compliance team to confirm.

How Venatech helps

One wearable BOM in, 0201 and 01005 options out. Venatech Limited, Walsin’s authorised distributor in Hong Kong, runs VenaMatch, which decodes part numbers from 18 manufacturers and crosses 800,000+ parts to Walsin, so a wearable capacitor list comes back with Walsin candidates in the current case and, where one exists, in 01005.

Paste part numbers into the cross-reference tool, or upload the BOM and request a quote through the site. The ready-stock snapshot, dated 9 November 2026, lists the 0201 lines on our shelf in Hong Kong. We are Hong Kong-based, handle small lots for prototype and verification builds, and confirm availability, date code and lead time on every quote. Walsin is our authorised line; Stackpole and Viking are lines we supply.

The short version

Cicor and CSEM have teamed up to take wearable health devices from concept to series production in Switzerland, Evertiq reported on 16 November 2026. Wearables are where boards move to the 01005 capacitor, which takes about 56 % less area than 0201. We counted 608 Walsin 01005 MLCC, mostly C0G, and 65 of the 100 0201 lines on our shelf in Hong Kong have an 01005 twin on dielectric, capacitance and tolerance.

Send us the capacitor list from your wearable board, and we will mark which positions have a Walsin 01005 twin. Which part of your board would you shrink first?

Related reading

Last reviewed: 21 November 2026

Sources

Fetched 21 November 2026.

  • Evertiq, “Cicor partners with CSEM on medical wearables”, 16 November 2026: https://evertiq.com/news/2026-11-16-cicor-partners-with-csem-on-medical-wearables
  • Walsin MLCC export, Venatech_MLCC_Upload_01.xlsx to Venatech_MLCC_Upload_08.xlsx, re-measured 21 November 2026; Walsin 01R5 and RF series datasheets; Venatech ready-stock snapshot dated 9 November 2026.

Frequently asked questions

What are Cicor and CSEM working on in Switzerland?

Wearable health monitoring, vital-signs sensing and connected medical devices, from feasibility study to series production, Evertiq reported on 16 November 2026.

How big is an 01005 capacitor?

0.40 x 0.20 mm, against 0.60 x 0.30 mm for 0201. Walsin codes the case as 01R5 in its part numbers.

How many Walsin 01005 capacitors are there?

We counted 608: 317 in the 01R5 ultra-small series and 291 in the RF series. 567 are C0G, 32 X5R and 9 X7R.

Can engineers in Switzerland replace 0201 capacitors with 01005 ones?

For 65 of the 100 0201 lines on our shelf, an 01005 twin exists on dielectric, capacitance and tolerance; 28 also keep the voltage. Check each twin’s rating and bias curve.

How high does Walsin 01005 capacitance go?

100 nF in X5R, for example 01R5X104K6R3 at 6.3 V. C0G parts reach 220 pF and X7R parts reach 1 nF.

Is Venatech an authorised Walsin distributor for Switzerland?

Venatech Limited is the authorised Walsin distributor in Hong Kong and supplies buyers in Switzerland in small lots. Stackpole and Viking are lines we supply, not authorised lines.


Share This, Choose Your Platform!