For an SMD Y2 capacitor in data centre power supplies built in India, Walsin Technology (Walsin) lists 160 X1/Y2 safety MLCC in its S2 series, from 3 pF to 10 nF in 1808, 1812, 2211 and 2220, rated Y2 250 Vac. Venatech Limited, an authorised Walsin distributor in Hong Kong, crosses your Y capacitors and quotes them.
This post is for engineers in India designing server, rack and telecom power supplies for the data-centre build-out, and for buyers sourcing their EMI and isolation parts. We counted every row of Walsin’s MLCC exports (Venatech_MLCC_Upload_01.xlsx to Venatech_MLCC_Upload_08.xlsx, 23,360 part numbers) and read the S2 rows against Walsin’s own safety datasheet, 16_Safety_X1Y2_General_S2.pdf. The forecast figure names its source and date.
What did Crisil forecast for India’s data centre capacity?
A roughly five-fold rise. IANS, as published by The Hans India on 3 November 2026, reported a Crisil Ratings forecast that India’s installed data centre capacity will rise about five-fold to roughly 7.5 GW by March 2030, with more than 3 lakh crore rupees of investment over four fiscal years.
The same report says about 6 GW of capacity is coming, with roughly three-fourths of it in Visakhapatnam, Mumbai and Hyderabad, and that nearly half of the upcoming capacity is already committed under long-term contracts of 15 to 20 years. We add no forecast of our own and name no operator or supplier. For a power engineer in India, every megawatt of that capacity runs through power supplies, rack shelves and backup units, and each of them filters common-mode noise to chassis through Y capacitors.
Where does an SMD Y2 capacitor sit in a data centre power supply?
Across the isolation barrier and from line to earth. A Y2 capacitor bridges line or primary to chassis earth, or primary to secondary, where its failure must not create a shock hazard; an X1/Y2 rated chip part lets the designer place it by reflow instead of hand-inserting a disc.
In a server or rack power supply you find Y capacitors in the input EMI filter, from each line to protective earth, and across the transformer isolation barrier to return common-mode current from the switching stage. Values are usually small, from hundreds of picofarads to a few nanofarads, because every Y capacitor adds leakage current to earth, and a rack full of supplies adds those leakage currents together. A surface-mount Y2 part saves board height and an assembly step, which matters in a dense 1U supply or a power shelf. Our guide to Y capacitor selection, disc vs chip compares the two formats field by field, and the MLCC range lists every series.
How many Walsin X1/Y2 safety MLCC are there, and in which sizes?
One hundred and sixty. We counted 160 distinct S2-series X1/Y2 safety MLCC: 49 in 1808, 34 in 1812, 57 in 2211 and 20 in 2220; 82 are X7R and 78 are C0G (NP0).
| Case size | C0G (NP0) | X7R | Total | Impulse rating in part number |
|---|---|---|---|---|
| 1808 (4520) | 28 | 21 | 49 | 5,000 V |
| 1812 (4532) | 18 | 16 | 34 | 5,000 V |
| 2211 (5728) | 32 | 25 | 57 | 5,000 V (47), 6,000 V (10) |
| 2220 (5750) | 0 | 20 | 20 | 5,000 V |
| Total | 78 | 82 | 160 |
The last three digits of each code are the impulse voltage, so 502 means a 5,000 V impulse rating and 602 means 6,000 V; the ten 602 parts are C0G parts in 2211 from 10 pF to 100 pF. The C0G parts cover small values for stable filtering; the X7R parts reach 10 nF. Ten parts sit at exactly 1 nF, across all four sizes and three tolerances.
Which Walsin SMD Y2 capacitor fits a 1 nF, 1812-or-smaller brief?
Two match at ±10%. For a brief of 1 nF, X7R, ±10%, X1/Y2 rated, in 1812 or smaller, S242B102K502 in 1808 and S243B102K502 in 1812 match; the 2211 and 2220 parts at 1 nF match electrically but need a bigger pad.
Put your incumbent Y capacitor in the last column and compare each field.
| Walsin part | Case | Capacitance | Tolerance | Dielectric | Match / mismatch with 1 nF, X7R, ±10%, 1812 or smaller | Your incumbent |
|---|---|---|---|---|---|---|
S242B102K502 |
1808 | 1 nF | ±10% | X7R | Match, smallest body | |
S243B102K502 |
1812 | 1 nF | ±10% | X7R | Match | |
S252B102K502 |
2211 | 1 nF | ±10% | X7R | Mismatch: case larger than 1812 | |
S255B102K502 |
2220 | 1 nF | ±10% | X7R | Mismatch: case larger than 1812 | |
S252B222K502 |
2211 | 2.2 nF | ±10% | X7R | Mismatch on value and case; on our shelf | |
S242B471K502 |
1808 | 470 pF | ±10% | X7R | Mismatch on value; fits a lower-leakage design |
Have part numbers to quote? Click any Walsin part number in the table to open its page and add it to your RFQ, or upload your BOM for a quote, or cross your current part in VenaMatch. E-mail sales@venatech.com.hk or call (852) 2628 4777. We confirm availability, date code and lead time on each quote.
A smaller value cuts leakage to earth but filters less common-mode current at low frequency, so the value is a trade the EMI test decides, not the catalogue.
What ratings and certificates does the Walsin S2 datasheet list?
Y2 at 250 Vac and X1 at 310 Vac. Walsin’s 16_Safety_X1Y2_General_S2.pdf lists the S2 series as X1 310 Vac and Y2 250 Vac under UL and TUV, 1,500 Vdc for all models, and 250 Vac under CQC, to EN, IEC and UL 60384-14.
The same datasheet lists TUV certificate R50381780, UL file E182369 and CQC certificate CQC20001280137 for the S2 series, each searchable in the issuing body’s own database. Those approvals belong to the Walsin part; your power supply’s own safety approval still depends on its layout, creepage, clearance and test results, which your compliance team and test house confirm.
Check the datasheet. Body thickness and the soft-termination and coated options are coded in the part number and printed on 16_Safety_X1Y2_General_S2.pdf; read the thickness for your exact code before you lay out a 1U supply.
Can Venatech supply Walsin SMD Y2 capacitors from Hong Kong?
Yes, from stock and to order. One S2 line, S252B222K502 (2.2 nF, 2211), is on our shelf in Hong Kong (snapshot 9 Nov 2026); the other 159 parts are quoted to order through our authorised Walsin channel.
We checked all 160 codes against that snapshot. Each quote states availability, date code and lead time for the line, and we work in small lots for engineering builds and EMI iterations. We make no stock, price or lead-time promise. The ready-stock list shows the full dated snapshot of MLCC and chip resistors.
How Venatech helps: what should an Indian power team send us?
The Y and X capacitors from your EMI filter. Venatech Limited, Walsin’s authorised distributor in Hong Kong, runs VenaMatch, which decodes part numbers from 18 manufacturers and crosses 800,000+ parts to Walsin, stating every field where the Walsin part differs from your original.
Paste a safety capacitor code into the cross-reference tool, or upload the whole BOM and request a quote through the site. The ready-stock snapshot is dated 9 November 2026. We serve Chennai, Hyderabad, Bengaluru and Pune from Hong Kong, with fast quotes and small lots. Walsin is the line we are authorised for; Stackpole and Viking are lines we supply.
The short version
Crisil expects India’s data centre capacity to reach about 7.5 GW by March 2030, roughly five times today’s, IANS reported via The Hans India on 3 November 2026. Every server and rack power supply filters noise to earth through Y capacitors. Walsin lists 160 SMD X1/Y2 safety MLCC rated Y2 250 Vac, and S243B102K502 meets a 1 nF, 1812 brief, with S242B102K502 in a smaller 1808 body.
Send us the Y capacitors from your input filter and we will return Walsin crosses with every difference stated. Is your Y capacitor still a hand-inserted disc?
Related reading
- Y capacitor selection: disc vs chip, S2 field by field
- Safety capacitor rated voltage explained
- Passives for AI server power stages
- Cross-reference tool, BOM upload and ready-stock snapshot
Last reviewed: 19 November 2026.
Sources
Fetched 19 November 2026.
- The Hans India (IANS), report on Crisil Ratings’ data centre capacity forecast, 3 November 2026: https://www.thehansindia.com/amp/business/indias-data-centre-capacity-set-for-5-fold-surge-by-2030-see-over-rs-3-lakh-crore-investments-1138856
- Walsin MLCC exports, Venatech_MLCC_Upload_01.xlsx to Venatech_MLCC_Upload_08.xlsx, re-measured 19 November 2026; Walsin safety datasheet 16_Safety_X1Y2_General_S2.pdf; Venatech Hong Kong stock snapshot dated 9 November 2026.
Frequently asked questions
What did Crisil forecast for India’s data centre capacity?
IANS reported on 3 November 2026 a Crisil Ratings forecast of about 7.5 GW of installed capacity by March 2030, roughly five times today’s level, with more than 3 lakh crore rupees of investment over four fiscal years.
What is an SMD Y2 capacitor used for in a power supply?
It connects line or primary to chassis earth, or primary to secondary, to return common-mode noise, and is rated so that its failure does not create a shock hazard. A chip part is placed by reflow instead of hand insertion.
How many Walsin X1/Y2 safety MLCC are available for buyers in India?
We counted 160 S2-series parts: 49 in 1808, 34 in 1812, 57 in 2211 and 20 in 2220, from 3 pF to 10 nF.
Which Walsin part crosses a 1 nF Y2 capacitor in 1812?
S243B102K502 matches in 1812 and S242B102K502 in 1808, both X7R at ±10%. Confirm thickness and your own safety layout before release.
What AC rating does the Walsin S2 series carry?
Walsin’s S2 datasheet lists Y2 250 Vac and X1 310 Vac under UL and TUV, 1,500 Vdc for all models, and 250 Vac under CQC.
Is Venatech an authorised Walsin distributor for buyers in India?
Venatech Limited is an authorised Walsin distributor in Hong Kong and serves buyers in India in small lots. Stackpole and Viking are lines we supply, not authorised lines.