NEWS

Anti-Sulfur Resistor Array for Industrial Automation in Canada: Ontario’s ATS Books 827 Million Canadian Dollars in a Quarter and 1,386 Walsin 0603 Arrays Cross Stackpole RAVS

An anti-sulfur resistor array keeps four pull-ups or line terminations in one footprint without the silver corrosion that sulfur gas causes in plant air. ATS, based in Cambridge, Ontario, booked 827 million Canadian dollars of orders in its September quarter, and Walsin lists 1,386 anti-sulfur arrays in 0603. Venatech is the authorised Walsin distributor in Hong Kong.


Venatech Limited, an authorised Walsin distributor in Hong Kong, wrote this for engineers and buyers at Ontario makers of automation cells, PLC and remote I/O modules, motion and process controllers. Walsin Technology (Walsin) is the line we are authorised for; Stackpole Electronics (SEI) is a line we supply, so a RAVS or RAVF already on your bill of materials can be quoted as it is or crossed to Walsin. We counted every Walsin figure below on 20 November 2026 in our Walsin anti-sulfur array export, Thick_Film_Chip_Resistor_Array_Anti_Sulfuration__1of1.xlsx, and checked our ready stock snapshot as at 9 November 2026. Stackpole figures come only from Stackpole’s resistor family page on seielect.com, fetched the same day.

How busy is Ontario’s automation industry in 2026?

Busy enough to lift orders by 12.7 percent. ATS Corporation of Cambridge, Ontario, reported on 4 November 2026 order bookings of 827 million Canadian dollars for the quarter to 27 September 2026, up 12.7 percent on a year earlier, with an order backlog of 2,009 million Canadian dollars.

The same release put life sciences backlog at 1,238 million Canadian dollars, a record for the company, and described a strong funnel in food and beverage automation. Those are ATS’s figures. Automation cells for pharmaceutical, medical-device and food lines are dense with electronics: PLC and safety I/O, servo drives, vision systems and sensor interfaces. Many of them run in plants where rubber, wastewater, cleaning chemicals or processing give the air a trace of sulfur, which is where an anti-sulfur part earns its place.

Why does an industrial I/O board need an anti-sulfur resistor array?

Because sulfur turns standard silver terminations open. Sulfur compounds in factory air react with the silver inner electrode of a standard thick film chip resistor and grow silver sulfide until the part reads high or opens; an anti-sulfur resistor array uses a sulfur-resistant termination system so a four-channel pull-up survives years in that air.

An array also saves placements. A 24-channel digital input card needs 24 input pull-downs and often 24 series resistors; in four-element arrays that is 12 placements instead of 48 on the same board. The power per element is small: a 10 kilohm pull-up at 3.3 V dissipates about 1 mW, far inside a 1/10 W 0603 element. Our resistor arrays vs discrete note covers the layout trade-offs, and anti-sulfuration resistor array: the intersection nobody counts explains how the two features combine.

How many Walsin 0603 anti-sulfur arrays cover the Stackpole RAVS range?

1,386. We filtered Walsin’s anti-sulfuration array export to the 0603 layouts and counted 1,386 distinct part numbers, 693 in the two-element and 693 in the four-element convex layout, from jumper to 1 megohm; 1,142 of them are at 1 percent.

Walsin anti-sulfur array subset (0603 convex) Distinct parts What our export states
All 0603 layouts 1,386 Jumper to 1 megohm
0603 four-element (SA06X) 693 1/10 W per element, 200 ppm
0603 two-element (SA06Y) 693 1/10 W per element, 200 ppm
At 1 percent 1,142 571 values in each layout
At 5 percent 242 121 values in each layout
Jumpers 2 One per layout
Same layouts in 0402 1,386 1/16 W, 300 ppm

Stackpole’s resistor family page, fetched 20 November 2026, describes RAVS as a convex anti-sulfur chip array offered in multiple circuit types at 1, 2 or 5 percent, and RAVF as a convex thick film chip array in 0402, 0603 and 1206 arrays from 1 ohm to 1 megohm. We have not seen the 0603 anti-sulfur layouts counted on their own anywhere else.

Which Walsin part crosses a Stackpole RAVS or RAVF array?

Most 0603 two- and four-element briefs at 1 or 5 percent. For an 0603 convex array with isolated elements at 1 or 5 percent up to 1 megohm, Walsin has an anti-sulfur SA part in the same layout and value; for 1206 arrays and 2 percent briefs, keep the Stackpole part.

Your brief (RAVS or RAVF style) Walsin part Walsin layout, tolerance, TCR, power (export) Match / mismatch Your incumbent
10 kilohm, 0603 x4, 1 percent SA06X1002FTL 0603 x4 convex, 1 percent, 200 ppm, 1/10 W, anti-sulfur Match on layout and value
4.7 kilohm, 0603 x4, 1 percent SA06X4701FTL 0603 x4 convex, 1 percent, 200 ppm, 1/10 W, anti-sulfur Match on layout and value
100 ohm, 0603 x4, 1 percent SA06X1000FTL 0603 x4 convex, 1 percent, 200 ppm, 1/10 W, anti-sulfur Match on layout and value; line termination
100 kilohm, 0603 x2, 1 percent SA06Y1003FTL 0603 x2 convex, 1 percent, 200 ppm, 1/10 W, anti-sulfur Match on layout and value
4.7 kilohm, 0402 x4, 1 percent SA04X4701FTL 0402 x4 convex, 1 percent, 300 ppm, 1/16 W, anti-sulfur Match on layout and value; check TCR
Any value, 1206 x4 array none in this export Walsin’s anti-sulfur arrays are 0402 and 0603 Mismatch: keep the RAVF, which we can quote
2 percent tolerance none in this export Walsin offers 1 and 5 percent Mismatch: 1 percent is tighter; confirm it suits your design

Have part numbers to quote? Click any Walsin part number in the table to open its page and add it to your RFQ, or upload your BOM for a quote, or cross your current part in VenaMatch. E-mail sales@venatech.com.hk or call (852) 2628 4777. We confirm availability, date code and lead time on each quote.

Check the datasheet. Our export states layout, value, tolerance, TCR and power per element. It does not state the pad pitch, the sulfur test method or the circuit diagram. Compare the land pattern and the element arrangement on both datasheets before you reuse a footprint.

What should an Ontario automation maker check before switching?

Footprint, then the sulfur test behind the claim. Confirm the array pitch and convex termination match your pad layout, confirm the elements are isolated rather than bussed, and compare the sulfur-exposure test each datasheet quotes, since anti-sulfur performance is only as good as the test condition stated.

TCR is rarely the issue for pull-ups: a 200 ppm element warming 40 degrees moves 0.8 percent, well inside any logic threshold. Matching between elements in one array is usually better than between discrete parts, which helps current-sharing and analogue input dividers. If your controllers carry a CSA or UL listing, a component change may need a review under that listing; that is your certifier’s call, and we give no compliance advice, so confirm with your compliance team.

How Venatech helps

Cross a whole I/O card bill of materials in one upload. Venatech is the authorised Walsin distributor in Hong Kong; VenaMatch decodes part numbers from 18 manufacturers and crosses 800,000+ parts to Walsin, stating size, value, tolerance, TCR and power as match or mismatch.

Paste your array lines into the cross-reference tool, or upload the parts list at BOM upload. On our shelf in Hong Kong (snapshot 9 Nov 2026) are 83 Walsin general purpose thick film lines in 0603 at 1 percent, including WR06X1002FTL at 10 kilohm and WR06X4701FTL at 4.7 kilohm, useful for discrete pull-ups on prototype boards; see ready stock. For the SA anti-sulfur arrays above, request a quote and we source them through our authorised Walsin channel. Stackpole RAVS and RAVF lines can be quoted too: Stackpole is a line we supply, and Walsin is the line we are authorised for. We serve Canadian buyers from Hong Kong in small lots and confirm availability, date code and lead time on each quote, with no price, lead-time or stock guarantee. The chip resistor range lists every Walsin family.

The short version

  • ATS of Cambridge, Ontario, booked 827 million Canadian dollars of orders in the quarter to 27 September 2026, up 12.7 percent, with a 2,009 million Canadian dollar backlog (ATS, 4 November 2026).
  • Walsin lists 1,386 anti-sulfur convex arrays in 0603, 693 in each of the two- and four-element layouts, 1,142 at 1 percent.
  • An 0603 RAVS or RAVF brief at 1 or 5 percent up to 1 megohm has a Walsin SA array in the same layout and value; keep the Stackpole part for 1206 arrays or 2 percent.
  • Check pad pitch, isolated elements and the sulfur test condition before you switch.

Send us the array lines from your I/O or controller board and we will return the Walsin crosses with every difference stated. How many discrete pull-ups on your input card could move into four-element arrays?

Related reading

Last reviewed: 20 November 2026.

Sources

Fetched 20 November 2026.

  • ATS Corporation, “ATS Reports Second Quarter Fiscal 2027 Results”, 4 November 2026: https://s201.q4cdn.com/979379719/files/doc_earnings/2027/q2/earnings-result/Q2-27-Press-Release.pdf
  • Stackpole Electronics resistor family page, fetched 20 November 2026: https://seielect.com/products/productsearch.asp?SelFamilyID=1
  • Venatech Walsin export (Thick_Film_Chip_Resistor_Array_Anti_Sulfuration__1of1.xlsx, Thick_Film_General_Purpose_1_1_10W.xlsx) and ready stock snapshot dated 9 November 2026, re-measured 20 November 2026.

Frequently asked questions

Which anti-sulfur resistor array suits a PLC input card in Canada?

For 10 kilohm pull-ups, Walsin’s SA06X1002FTL is a four-element 0603 convex array at 1 percent, 200 ppm and 1/10 W per element, with anti-sulfur terminations. Four channels take one placement.

How many Walsin 0603 anti-sulfur arrays cross the Stackpole RAVS range?

1,386 in our export, 693 in the two-element and 693 in the four-element 0603 layout, from jumper to 1 megohm. 1,142 are at 1 percent.

Does Walsin make a 1206 anti-sulfur resistor array?

Not in the anti-sulfuration array export we hold, which covers 0402 and 0603. Keep the Stackpole RAVF for 1206 arrays; we can quote it.

Does an anti-sulfur array need a tighter TCR for pull-ups?

Rarely. A 200 ppm element warming 40 degrees moves 0.8 percent, well inside a logic threshold; check TCR only where the array forms an analogue divider.

Do you hold resistors on the shelf in Hong Kong for Ontario prototypes?

83 Walsin general purpose 0603 lines at 1 percent are on our shelf in Hong Kong (snapshot 9 Nov 2026), including WR06X1002FTL and WR06X4701FTL. For SA arrays, request a quote and we source them through our authorised Walsin channel.

How does Venatech supply Stackpole?

Stackpole is a line we supply, not an authorised line; Venatech is the authorised Walsin distributor in Hong Kong. We quote the Stackpole array alongside the Walsin cross.


Share This, Choose Your Platform!