Inductor DCR loss is current squared times DC resistance. At 1.5 A, a 196 milliohm part burns 0.44 W, 8.9 percent of a 3.3 V, 4.95 W output; a 26.3 milliohm part burns 0.06 W, 1.2 percent. Of 52 Walsin 4.7 uH inductors, 3 stay under 2 percent hot. Venatech is the authorised Walsin distributor in Hong Kong.
Venatech Limited, an authorised Walsin distributor in Hong Kong, wrote this for power-supply engineers in Santiago, Antofagasta and across Chile who design the small DC-DC stages inside solar trackers, string monitors, weather stations, battery-storage controllers and mine-site instruments, and for the buyers who source their inductors. Walsin Technology (Walsin) is the line we are authorised for. On 18 November 2026 we parsed our two inductor upload files, Venatech_Inductor_Upload_01.xlsx and Venatech_Inductor_Upload_02.xlsx, filtered every microhenry part to 4.7 uH, and computed copper loss from each row’s DC resistance at a stated load. Every part number below is real.
How much solar electronics does Chile run in 2026?
About 14,100 MW of solar on a 41,196 MW grid. Reporte Minero reported on 6 October 2026, citing the Coordinador Electrico Nacional’s monthly report, that Chile’s national electricity system reached 41,196.1 MW of installed capacity at the end of August 2026, with solar at 14,099.98 MW, or 34.2 percent of the total.
Those are the coordinator’s figures as reported, not ours. Behind every megawatt of utility solar sits a layer of small electronics: tracker controllers that run from a local panel and battery, string and combiner monitors, meteorological stations, communication gateways. Each has a low-voltage supply, usually a buck converter from 12 or 24 V down to 5 or 3.3 V, and most of those are built around a power inductor in the microhenry range. In a desert site with a hot enclosure and, for tracker controllers, a limited energy budget, the inductor’s DC resistance is a loss you pay every hour of the day.
How do you calculate inductor DCR loss in a buck converter?
Multiply the square of the DC current by the DCR. For a 12 V to 3.3 V buck at 1.5 A, a 4.7 uH inductor with 196 milliohms of DCR dissipates 1.5 squared times 0.196, or 0.44 W, against an output of 4.95 W; at 26.3 milliohms the loss falls to 0.059 W.
In a buck converter the inductor carries the load current plus a triangular ripple, so the true RMS current is a little higher than the DC current; for ripple of 30 percent peak to peak it is less than 0.4 percent higher, small enough to ignore in a first pass. What the DCR figure does not capture is core loss and AC winding loss, which grow with ripple and switching frequency. Check the datasheet: Walsin’s parametric export gives DCR and rated current, not core-loss curves, so read the loss data for your switching frequency before you sign off. Our guide to reading inductor DC resistance explains how DCR is specified, typical versus maximum.
How much does DCR rise when the inductor gets hot?
About 25 percent from 20 C to 85 C. Copper’s resistance rises by about 0.393 percent per degree, so a winding at 85 C has 1.255 times its 20 C resistance: a 196 milliohm part becomes about 246 milliohms and loses 0.55 W at 1.5 A, while a 29.5 milliohm part becomes 37.0 milliohms and loses 0.083 W.
That is why we set the budget hot. If copper loss may be at most 2 percent of a 4.95 W output, 0.099 W, the hot DCR may be at most 44 milliohms at 1.5 A, and the room-temperature DCR printed in the export at most about 35 milliohms. A tracker enclosure in the Atacama sun can sit well above the outside air temperature, so 85 C at the winding is not an extreme assumption. Check the datasheet for the temperature at which Walsin specifies DCR.
Which Walsin 4.7 uH inductors keep DCR loss under 2 percent at 1.5 A?
Three AIP parts. We counted 52 distinct Walsin part numbers at 4.7 uH across 15 series; for a 1.5 A, 3.3 V brief with a 2 percent hot copper-loss budget, AIP0630GX-4R7MPB at 26.3 milliohms, AIP0630MB-4R7M at 27.9 and AIP0530GX-4R7MPB at 29.5 match, and the smaller parts miss on loss.
| Brief: 4.7 uH, 1.5 A, 3.3 V out, copper loss under 2% at 85 C | Walsin part | Series | Size, height | DCR | Rated current | Loss at 1.5 A, 20 C / 85 C | Share of 4.95 W, hot | Match / mismatch |
|---|---|---|---|---|---|---|---|---|
| Lowest DCR | AIP0630GX-4R7MPB |
AIP | 7.2 x 6.5 mm, 3.0 mm | 26.3 mOhm | 7.1 A | 0.059 / 0.074 W | 1.5% | Match |
| Lower profile at the same footprint | AIP0630MB-4R7M |
AIP | 7.0 x 6.6 mm, 2.8 mm | 27.9 mOhm | 6 A | 0.063 / 0.079 W | 1.6% | Match |
| Smaller footprint | AIP0530GX-4R7MPB |
AIP | 5.7 x 5.4 mm, 3.0 mm | 29.5 mOhm | 5.9 A | 0.066 / 0.083 W | 1.7% | Match |
| Mid size | AIP0518MB-4R7M |
AIP | 5.4 x 5.2 mm, 1.6 mm | 70 mOhm | 3.5 A | 0.158 / 0.198 W | 4.0% | Mismatch on loss |
| Thin, large | AIP0615MB-4R7M |
AIP | 7.0 x 6.6 mm, 1.3 mm | 85 mOhm | 3.2 A | 0.191 / 0.240 W | 4.8% | Mismatch on loss |
| Compact | AIP0420MB-4R7M |
AIP | 4.4 x 4.2 mm, 1.8 mm | 89 mOhm | 2.8 A | 0.200 / 0.251 W | 5.1% | Mismatch on loss |
| Compact, with saturation figure | CSMM0420D-4R7M |
CSME | 4.0 x 4.0 mm, 1.8 mm | 115 mOhm | 2.85 A | 0.259 / 0.325 W | 6.6% | Mismatch on loss |
| Chip-size, higher current grade | WLPH252012M4R7PS |
WLPH(HC) | 2.5 x 2.0 mm, 1.2 mm | 150 mOhm | 1.8 A | 0.338 / 0.424 W | 8.6% | Mismatch on loss and current margin |
| Chip-size | WLPH252012M4R7PP |
WLPH | 2.5 x 2.0 mm, 1.2 mm | 196 mOhm | 1.61 A | 0.441 / 0.553 W | 11.2% | Mismatch; fits below about 0.5 A |
Have part numbers to quote? Click any Walsin part number in the table to open its page and add it to your RFQ, or upload your BOM for a quote, or cross your current part in VenaMatch. E-mail sales@venatech.com.hk or call (852) 2628 4777. We confirm availability, date code and lead time on each quote.
We checked each row’s DCR, rated current, size and height in the export. WLPH252012M4R7PP is on our shelf in Hong Kong (snapshot 9 Nov 2026), and it is the right part for what it is: a 2.5 x 2.0 mm, 1.2 mm high inductor for a sub-amp rail, where at 0.5 A its hot loss is 0.06 W. At 1.5 A it is the wrong part. The AIP parts are to order: request a quote and we source them through our authorised Walsin channel. Check the datasheet for saturation current on the AIP parts, which the export leaves blank.
What do you trade for low DCR: size, height or current?
Mostly volume. The three matching parts occupy 31 to 47 square millimetres at 2.8 to 3.0 mm high, against 5 square millimetres at 1.2 mm for the WLPH chip part: six to nine times the footprint buys about one seventh of the DCR.
The physics is plain: lower DCR needs thicker or shorter copper, which needs a bigger core window. Height is the second lever: AIP0615MB-4R7M keeps the large 7.0 x 6.6 mm footprint but at 1.3 mm high it carries 85 milliohms, three times the 2.8 mm version. If height is the constraint, a lower inductance with a higher switching frequency can recover DCR; our guide to choosing an inductor for a buck converter walks through that trade, and Walsin power inductors above 1 A maps the families. The inductor range page lists every series.
How Venatech helps: what can a Chilean solar electronics team send us?
Your power-stage inductors with their load currents. Venatech is the authorised Walsin distributor in Hong Kong; VenaMatch decodes part numbers from 18 manufacturers and crosses 800,000+ parts to Walsin, including the 52 Walsin 4.7 uH inductors above.
Paste your inductor lines into the cross-reference tool, upload the BOM at /bom/, or check the dated ready stock list. We serve Chile from Hong Kong in small lots, which suits prototypes, field trials and service spares, and we quote fast. We confirm availability, date code and lead time on each quote and promise none in advance; thermal and efficiency validation stays with your engineers, and import questions with your compliance team.
The short version
- Chile’s grid reached 41,196.1 MW at the end of August 2026, with 14,099.98 MW of solar, 34.2 percent (Coordinador Electrico Nacional via Reporte Minero, 6 October 2026).
- Inductor DCR loss is I squared R: at 1.5 A, 196 milliohms costs 0.44 W and 26.3 milliohms costs 0.059 W.
- Copper DCR rises about 25 percent from 20 C to 85 C; set the loss budget hot.
- Of 52 Walsin 4.7 uH parts, AIP0630GX-4R7MPB, AIP0630MB-4R7M and AIP0530GX-4R7MPB keep hot copper loss under 2 percent at 1.5 A.
Send us the inductor and load current from each rail and we will return the Walsin crosses with DCR loss computed. How much of your supply’s loss is sitting in one small inductor?
Related reading
- Reading inductor DC resistance
- Choosing an inductor for a buck converter
- Walsin power inductors above 1 A
- Cross-reference tool, BOM upload and ready stock snapshot
Last reviewed: 18 November 2026.
Sources
Fetched 18 November 2026.
- Reporte Minero, Capacidad instalada del Sistema Electrico Nacional llega a 41.196 MW, 6 October 2026, citing the Coordinador Electrico Nacional monthly report: https://www.reporteminero.cl/noticia/noticias/2026/10/capacidad-instalada-sistema-electrico-nacional-41196-mw-energia-solar-2026
- Venatech inductor upload files Venatech_Inductor_Upload_01.xlsx and _02.xlsx, with the datasheet links in each row (AIP0630GX-MPB.pdf, AIP0630MB.pdf, AIP0530GX-MPB.pdf, WLPH252012_P.pdf), re-measured 18 November 2026; Venatech ready stock snapshot dated 9 November 2026.
Frequently asked questions
How do I calculate inductor DCR loss?
Square the DC current and multiply by the DCR. At 1.5 A and 29.5 milliohms that is 0.066 W; at 196 milliohms it is 0.44 W.
How much does inductor DCR increase with temperature?
About 0.393 percent per degree for copper, so roughly 25 percent from 20 C to 85 C. Budget the loss with the hot value.
Which Walsin 4.7 uH inductor has the lowest DCR?
In our count of 52 parts, AIP0630GX-4R7MPB at 26.3 milliohms and 7.1 A rated current, 7.2 x 6.5 mm and 3.0 mm high.
Is a 2520 chip inductor good enough for a 1.5 A buck?
At 4.7 uH, not for efficiency: WLPH252012M4R7PP has 196 milliohms and 1.61 A rated current, so it loses about 11 percent of a 4.95 W output when hot. It suits rails below about 0.5 A.
Does DCR loss include core loss?
No. DCR loss is the DC copper loss only; core loss and AC winding loss depend on ripple and frequency. Check the datasheet curves.
Can Venatech supply power inductors to Chile?
Yes. Venatech is the authorised Walsin distributor in Hong Kong and quotes small lots to Chile; one 4.7 uH WLPH line is on our shelf in Hong Kong (snapshot 9 Nov 2026) and the AIP parts are quoted through our authorised channel.